Mental Arithmetic Dataset from Shin et al 2017
Data Acquisition
EEG and NIRS data was collected in an ordinary bright room. EEG data was
recorded by a multichannel BrainAmp EEG amplifier with thirty active
electrodes (Brain Products GmbH, Gilching, Germany) with linked mastoids
reference at 1000 Hz sampling rate. The EEG amplifier was also used to
measure the electrooculogram (EOG), electrocardiogram (ECG) and respiration
with a piezo based breathing belt. Thirty EEG electrodes were placed on a
custom-made stretchy fabric cap (EASYCAP GmbH, Herrsching am Ammersee,
Germany) and placed according to the international 10-5 system (AFp1, AFp2,
AFF1h, AFF2h, AFF5h, AFF6h, F3, F4, F7, F8, FCC3h, FCC4h, FCC5h, FCC6h, T7,
T8, Cz, CCP3h, CCP4h, CCP5h, CCP6h, Pz, P3, P4, P7, P8, PPO1h, PPO2h, POO1,
POO2 and Fz for ground electrode).
NIRS data was collected by NIRScout (NIRx GmbH, Berlin, Germany) at 12.5 Hz
sampling rate. Each adjacent source-detector pair creates one physiological
NIRS channel. Fourteen sources and sixteen detectors resulting in
thirty-six
physiological channels were placed at frontal (nine channels around Fp1,
Fp2, and Fpz), motor (twelve channels around C3 and C4, respectively) and
visual areas (three channels around Oz). The inter-optode distance was 30
mm. NIRS optodes were fixed on the same cap as the EEG electrodes. Ambient
lights were sufficiently blocked by a firm contact between NIRS optodes and
scalp and use of an opaque cap.
EOG was recorded using two vertical (above and below left eye) and two
horizontal (outer canthus of each eye) electrodes. ECG was recorded based
on
Einthoven triangle derivations I and II, and respiration was measured using
a respiration belt on the lower chest. EOG, ECG and respiration were
sampled
at the same sampling rate of the EEG. ECG and respiration data were not
analyzed in this study, but are provided along with the other signals.
Experimental Procedure
The subjects sat on a comfortable armchair in front of a 50-inch white
screen. The distance between their heads and the screen was 1.6 m. They
were
asked not to move any part of the body during the data recording. The
experiment consisted of three sessions of left and right hand MI (dataset
A)and MA and baseline tasks (taking a rest without any thought) (dataset B)
each. Each session comprised a 1 min pre-experiment resting period, 20
repetitions of the given task and a 1 min post-experiment resting
period. The task started with 2 s of a visual introduction of the task,
followed by 10 s of a task period and resting period which was given
randomly from 15 to 17 s. At the beginning and end of the task period, a
short beep (250 ms) was played. All instructions were displayed on the
white
screen by a video projector. MI and MA tasks were performed in separate
sessions but in alternating order (i.e., sessions 1, 3 and 5 for MI
(dataset
A) and sessions 2, 4 and 6 for MA (dataset B)). Fig. 2 shows the schematic
diagram of the experimental paradigm. Five sorts of motion artifacts
induced
by eye and head movements (dataset C) were measured. The motion artifacts
were recorded after all MI and MA task recordings. The experiment did not
include the pre- and post-experiment resting state periods.
Mental Arithmetic (Dataset B)
For the visual instruction of the MA task, an initial subtraction such as
'three-digit number minus one-digit number' (e.g., 384-8) appeared at the
center of the screen for 2 s. The subjects were instructed to memorize the
numbers while the initial subtraction was displayed on the screen. The
initial subtraction disappeared with a short beep sound and a black
fixation cross was displayed during the task period in which the subjects
were asked
to repeatedly perform to subtract the one-digit number from the result of
the previous subtraction. For the baseline task, no specific sign but the
black fixation cross was displayed on the screen, and the subjects were
instructed to take a rest. Note that there were other rest periods between
the MA and baseline task periods, as same with the MI paradigm. Both task
periods were finished with a short beep sound and a 'STOP' displayed for
1 s on the screen. The fixation cross was displayed again during the rest
period. MA and baseline trials were randomized in the same way as MI.
References
----------
[1] Shin, J., von Lühmann, A., Blankertz, B., Kim, D.W., Jeong, J.,
Hwang, H.J. and Müller, K.R., 2017. Open access dataset for EEG+NIRS
single-trial classification. IEEE Transactions on Neural Systems
and Rehabilitation Engineering, 25(10), pp.1735-1745.
https://ieeexplore.ieee.org/document/7742400/
[2] GNU General Public License, Version 3
<https://www.gnu.org/licenses/gpl-3.0.txt>_