3D CBCT Challenge 2024: Improved Cone Beam CT Reconstruction using SwinIR-Based Sinogram and Image Enhancement
In this paper, we present our approach to the 3D CBCT Challenge 2024, a part of ICASSP SP Grand Challenges 2024. Improvement in Cone Beam Computed Tomography (CBCT) reconstruction has been achieved by integrating Swin Image Restoration (SwinIR) based sinogram and image enhancement modules. The proposed methodology uses Nesterov Accelerated Gradient Descent (NAG) to solve the least squares (NAG-LS) problem in CT image reconstruction. The integration of sinogram and image enhancement modules aims to enhance image clarity and preserve fine details, offering a promising solution for both low dose and clinical dose CBCT reconstruction. The averaged mean squared error (MSE) over the validation dataset has decreased significantly, in the case of low dose by one-fifth and clinical dose by one-tenth. Our solution is one of the top 5 approaches in this challenge.
Code (0)
등록된 구현이 없습니다.
Tasks
CT ReconstructionImage EnhancementImage ReconstructionImage RestorationMethods 이 논문이 사용한 방법론
Similar Papers 제목 키워드 기반
Equivariant Multiscale Learned Invertible Reconstruction for Cone Beam CT: From Simulated to Real Data
Cone Beam CT (CBCT) is an important imaging modality nowadays, however lower image quality of CBCT compared to more conventional Computed Tomography (CT) remains a limiting factor in CBCT applications. Deep learning reco…
Splat-based Metal Artifact Reduction in Cone-Beam CT via Polychromatic Modeling
Cone-beam computed tomography (CBCT) enables volumetric reconstruction from X-ray projections, but suffers from severe artifacts--especially beam hardening--when imaging materials with high attenuation such as metals. Th…
Limited-Angle CBCT Reconstruction via Geometry-Integrated Cycle-domain Denoising Diffusion Probabilistic Models
Cone-beam CT (CBCT) is widely used in clinical radiotherapy for image-guided treatment, improving setup accuracy, adaptive planning, and motion management. However, slow gantry rotation limits performance by introducing …
ARCDenoisingSSIMNonlinear ill-posed problem in low-dose dental cone-beam computed tomography
This paper describes the mathematical structure of the ill-posed nonlinear inverse problem of low-dose dental cone-beam computed tomography (CBCT) and explains the advantages of a deep learning-based approach to the reco…
Image ReconstructionAn Iterative Reconstruction Method for Dental Cone-Beam Computed Tomography with a Truncated Field of View
In dental cone-beam computed tomography (CBCT), compact and cost-effective system designs often use small detectors, resulting in a truncated field of view (FOV) that does not fully encompass the patient's head. In itera…