paper-with-me

Papers

Greedy-optimized Approach for Interbeat Interval and Heart Rate Variability Daily Monitoring using Wearable PPG

2023-01-07 · Luffina C. Huang

Continuous monitoring of heart rate variability (HRV) provides insights in cardiovascular health. Wearable Photoplethysmography (PPG) assures convenient measurement of HRV. PPG, however, is susceptible to motion artifacts, considerably deteriorating the accuracy in estimation. In this study, a greedy-optimized approach is proposed for attaining high accuracy of interbeat intervals (IBIs) estimation from PPG signals collected during intensive daily activities. Utilizing the fact of continuity in heartbeats, the IBI estimation is converted into the shortest path problem in a directed acyclic graph, where candidate heartbeats from motion-contaminated PPG are regarded as vertices. The approach exploits a convex penalty function to optimize weight assignment in the shortest path calculation and a greedy fusion method to strengthen the selection process of optimal IBIs. Results achieve correlation of 0.96 for IBI estimation with the improvement of 58.4% in percentage error on the single-channel PPG signal from 2015 IEEE Signal Processing Cup. It also achieves correlation of 0.98 with percentage error of 2.2% in the two-channel PPG signal. Estimated and true HRV parameters are highly correlated. The approach is further validated on the PPG-DaLiA dataset with high correlation and low percentage error for IBI and HRV estimation in two daily activities, indicating the robustness of the proposed technique.

📄 PDF Abstract BibTeX arXiv:2301.02906

Code (0)

등록된 구현이 없습니다.

Tasks

Heart Rate VariabilityPhotoplethysmography (PPG)

Similar Papers 제목 키워드 기반

Accurate Radar-Based Heartbeat Measurement Using Higher Harmonic Components

2024-07-10 · Itsuki Iwata, Kimitaka Sumi, Yuji Tanaka, Takuya Sakamoto

This study proposes a radar-based heartbeat measurement method that uses the absolute value of the second derivative of the complex radar signal, rather than its phase, and the variational mode extraction method, which i…

Interbeat Interval Filtering

2024-06-03 · Ilker Bayram

A number of inhibitory and excitatory factors regulate the beating of the heart. Consequently, the inter-beat intervals (IBIs) are not constant but vary around a mean value, even in the absence of external factors like e…

Heart Rate Variability

Statistical model for describing heart rate variability in normal rhythm and atrial fibrillation

2022-07-17 · Nikita Markov, Ilya Kotov, Konstantin Ushenin, Yakov Bozhko

Heart rate variability (HRV) indices describe properties of interbeat intervals in electrocardiogram (ECG). Usually HRV is measured exclusively in normal sinus rhythm (NSR) excluding any form of paroxysmal rhythm. Atrial…

Heart Rate VariabilityRhythm

Ballistocardiogram Signal Processing: A Literature Review

2018-07-03 · Ibrahim Sadek

Time-domain algorithms are focused on detecting local maxima or local minima using a moving window, and therefore finding the interval between the dominant J-peaks of ballistocardiogram (BCG) signal. However, this approa…

Heart Rate Variability

Camera PPG waveforms at the forehead

2023-06-16 · A. C. den Brinker, H. H. Der Sarkissian, J. H. Wülbern, B. Balmaekers 외

In order to obtain insights into the feasibility of replacing ECG-guided triggering in magnetic resonance imaging (MRI) by a system based on video photoplethysmography (PPG), PPG and ECG data were collected from voluntee…

Photoplethysmography (PPG)