paper-with-me

Papers

A simple device for microinjections, manipulations and measurements using an electromorphological chip under microinterferometric control of the interface and membrane processes at the thickness range of 5-1000 nm at different angles

2018-07-23 · O. V. Gradov, P. A. Nasirov, A. A. Scrynnic, A. G. Jablokov

Micromanipulations, perfusions and measurements performed using glass microelectrodes filled with an electrolyte is a conventional technique for experimental morphological and membrane electrophysiological studies at a single cell and membrane surface level. The typical (effective) diameter of the end of the glass microelectrode is from 500 up to less than 100 nm, which prevents one from observing it using a standard optical microscope in accordance with the optical resolution criteria, since the diameter less than 500 nm is indistinguishable within the interference zone. Microprocessor programming of the puller (microforge) that provides pulling and tearing allows to obtain in certain regimes the adjusted diameter and shape of the micropipette tip, although this result is not fully controlled due to the above limitations. In this connection it is necessary to design the control devices for the micropipette tips both at the preparation and operation stages (intracellular or extracellular insertion). This method also should provide visualization of the processes occurring upon interaction of the microelectrode tip with the cell in real time, depending on the electrode type and state, which allows to level the artifacts arising with the systematic error frequency from the uncontrolled operation of the micropipette tip after different ways of the microelectrode filling with the electrolyte. We propose an installation scheme that solves the above problems by means of introducing an interferometric device for microscopic control of the microelectrode and micromanipulator or microperfusor, for the first time for a given type of optical instruments combined with the interferometric optical scheme.

📄 PDF Abstract BibTeX arXiv:1807.10137

Code (0)

등록된 구현이 없습니다.

Similar Papers 제목 키워드 기반

Afford-X: Generalizable and Slim Affordance Reasoning for Task-oriented Manipulation

2025-03-05 · Xiaomeng Zhu, Yuyang Li, Leiyao Cui, Pengfei Li 외

Object affordance reasoning, the ability to infer object functionalities based on physical properties, is fundamental for task-oriented planning and activities in both humans and Artificial Intelligence (AI). This capabi…

ObjectObject Recognition

Clinical Applications of Plantar Pressure Measurement

2024-01-09 · Kelsey Detels, David Shin, Harrison Wilson, Shanni Zhou 외

Plantar pressure measurements can provide valuable insight into various health characteristics in patients. In this study, we describe different plantar pressure devices available on the market and their clinical relevan…

Adaptive conditional latent diffusion maps beam loss to 2D phase space projections

2025-02-25 · Alexander Scheinker, Alan Williams

Beam loss (BLM) and beam current monitors (BCM) are ubiquitous at particle accelerator around the world. These simple devices provide non-invasive high level beam measurements, but give no insight into the detailed 6D (x…

Beyond PRNU: Learning Robust Device-Specific Fingerprint for Source Camera Identification

2021-11-03 · Manisha, Chang-Tsun Li, Xufeng Lin, Karunakar A. Kotegar

Source camera identification tools assist image forensic investigators to associate an image in question with a suspect camera. Various techniques have been developed based on the analysis of the subtle traces left in th…

A Robot Web for Distributed Many-Device Localisation

2022-02-07 · Riku Murai, Joseph Ortiz, Sajad Saeedi, Paul H. J. Kelly 외

We show that a distributed network of robots or other devices which make measurements of each other can collaborate to globally localise via efficient ad-hoc peer to peer communication. Our Robot Web solution is based on…