Accelerometric Method for Cuffless Continuous Blood Pressure Measurement

2020-08-18 · Mousumi Das, Tilendra Choudhary, L. N. Sharma, M. K. Bhuyan

Pulse transit time (PTT) has been widely used for cuffless blood pressure (BP) measurement. But, it requires more than one cardiovascular signals involving more than one sensing device. In this paper, we propose a method for continuous cuffless blood pressure measurement with the help of left ventricular ejection time (LVET). The LVET is estimated using a signal obtained through a micro-electromechanical system (MEMS)-based accelerometric sensor. The sensor acquires a seismocardiogram (SCG) signal at the chest surface, and the LVET information is extracted. Both systolic blood pressure (SBP) and diastolic blood pressure (DBP) are estimated by calibrating the system with the original arterial blood pressure values of the subjects. The proposed method is evaluated using different quantitative measures on the signals collected from ten subjects under the supine position. The performance of the proposed method is also compared with two earlier approaches, where PTT intervals are estimated from electrocardiogram (ECG)-photoplethysmogram (PPG) and SCG-PPG, respectively. The performance results clearly show that the proposed method is comparable with the state-of-the-art methods. Also, the computed blood pressure is compared with the original one, measured through a CNAP system. It gives the mean errors of the estimated systolic BP and diastolic BP within the range of -0.19 +/- 3.3 mmHg and -1.29 +/- 2.6 mmHg, respectively. The mean absolute errors for systolic BP and diastolic BP are 3.2 mmHg and 2.6 mmHg, respectively. The accuracy of BPs estimated from the proposed method satisfies the requirements of the IEEE standard of 5 +/- 8 mmHg deviation, and thus, it may be used for ubiquitous long term blood pressure monitoring.

📄 PDF Abstract BibTeX arXiv:2008.07899

Code (0)

등록된 구현이 없습니다.

Similar Papers 제목 키워드 기반

Feature Exploration for Knowledge-guided and Data-driven Approach Based Cuffless Blood Pressure Measurement

2019-08-27

This study explores extended feature space that is indicative of blood pressure (BP) changes for better estimation of continuous BP in an unobtrusive way. A total of 222 features were extracted from noninvasively acquire…

Large Language Models for Cuffless Blood Pressure Measurement From Wearable Biosignals

2024-06-26 · Zengding Liu, Chen Chen, Jiannong Cao, Minglei Pan 외

Large language models (LLMs) have captured significant interest from both academia and industry due to their impressive performance across various textual tasks. However, the potential of LLMs to analyze physiological ti…

Development of a One Dollar Blood Pressure Monitor

2023-08-11 · Yinan Xuan, Ava J. Fascetti, Colin Barry, Edward J. Wang

BPClip is an ultra-low-cost cuffless blood pressure monitor. As a universal smartphone attachment, BPClip leverages the computational imaging power of smartphones to perform oscillometry based blood pressure measurements…

BP-DeepONet: A new method for cuffless blood pressure estimation using the physcis-informed DeepONet

2024-02-29 · Lingfeng li, Xue-Cheng Tai, Raymond Chan

Cardiovascular diseases (CVDs) are the leading cause of death worldwide, with blood pressure serving as a crucial indicator. Arterial blood pressure (ABP) waveforms provide continuous pressure measurements throughout the…

Blood pressure estimationDiagnosticMeta-Learning

Single-Beat Cuffless Blood Pressure Estimation Using Ear-PPG and ECG with a Lightweight Hybrid Learning Framework

2026-07-29 · Kindeep K. Dhatt, Tengyue Wu, Hanbang Hua, Yayun Du arxiv

Continuous cuffless blood pressure (BP) monitoring remains challenging due to motion artifacts, physiological variability, and the limited robustness of conventional pulse transit time (PTT) models under dynamic conditio…

Blood pressure estimation