Assessment of the Center of Inertia and Regional Inertia with Load Contribution via a Fully Data-Driven Method

2022-06-20 · Lucas Lugnani, Mario Paternina, Daniel Dotta

This paper proposes a new comprehensive and fully data-driven methodology to estimate the center of inertia (COI) and the regional inertia, considering the displacement of the COI due to disturbances and load inertial contributions. The strategy uses the typicality-based data analysis (TDA) technique to detect the right pilot-bus that represents the COI. In the TDA, a compound of correlation and cosine similarities is implemented to approximate the actual distribution of the data and find the point (bus) closest to the mean which is elected as the pilot-bus. Then, the frequency response at the pilot-bus and the active power deviations are embedded into an autoregressive moving average exogenous input (ARMAX)-based approach to determine the regional inertia represented by an equivalent machine, whose inertia constant corresponds to the inertial contribution in the Region. % the This is done in order to perform the inertial estimation of the region using the frequency response of the pilot-bus and the active power of the region interconnections to model the region as and equivalent machine whose inertial constant is estimated using ARMAX identification technique. The methodology is tested using the IEEE 68-bus benchmark test system and an adapted version with aggregated dynamical loads, corroborating the method effectiveness.

📄 PDF Abstract BibTeX arXiv:2206.10036

Code (0)

등록된 구현이 없습니다.

Methods 이 논문이 사용한 방법론

Test 설명 없음

Similar Papers 제목 키워드 기반

Identifying the Largest RoCoF and Its Implications

2024-04-02 · Licheng Wang, Luochen Xie, Gang Huang, Changsen Feng

The rate of change of frequency (RoCoF) is a critical factor in ensuring frequency security, particularly in power systems with low inertia. Currently, most RoCoF security constrained optimal inertia dispatch methods and…

Dynamic Estimation of Power System Inertia Distribution Using Synchrophasor Measurements

2020-06-20 · Mingjian Tuo, Xingpeng Li

Integration of intermittent renewable energy sources in modern power systems is increasing very fast. Replacement of synchronous generators with zero-to-low variable renewables substantially decreases the system inertia.…

Clustering

Oscillations-Aware Frequency Security Assessment via Efficient Worst-Case Frequency Nadir Computation

2024-02-26 · Yan Jiang, Hancheng Min, Baosen Zhang

Frequency security assessment following major disturbances has long been one of the central tasks in power system operations. The standard approach is to study the center of inertia frequency, an aggregate signal for an …

Joint Estimation of System Inertia and Load Relief

2021-10-02 · Julius Susanto, Alireza Fereidouni, Dean Sharafi

Modern power systems with high share of renewable generation are at the risk of rapid changes in frequency and inertia resulting from contingencies. The importance of an accurate assessment of system and load relief, as …

Estimation of Payload Inertial Parameters from Human Demonstrations by Hand Guiding

2025-07-21 · Johannes Hartwig, Philipp Lienhardt, Dominik Henrich arxiv