Autoencoder-Based Denoising of Muscle Artifacts in ECG to Preserve Skin Nerve Activity (SKNA) for Cognitive Stress Detection
The sympathetic nervous system (SNS) plays a central role in regulating the body's responses to stress and maintaining physiological stability. Its dysregulation is associated with a wide range of conditions, from cardiovascular disease to anxiety disorders. Skin nerve activity (SKNA) extracted from high-frequency electrocardiogram (ECG) recordings provides a noninvasive window into SNS dynamics, but its measurement is highly susceptible to electromyographic (EMG) contamination. Traditional preprocessing based on bandpass filtering within a fixed range (e.g., 500--1000 Hz) is susceptible to overlapping EMG and SKNA spectral components, especially during sustained muscle activity. We present a denoising approach using a lightweight one-dimensional convolutional autoencoder with a long short-term memory (LSTM) bottleneck to reconstruct clean SKNA from EMG-contaminated recordings. Using clean ECG-derived SKNA data from cognitive stress experiments and EMG noise from chaotic muscle stimulation recordings, we simulated contamination at realistic noise levels (--4 dB, --8 dB signal-to-noise ratio) and trained the model in the leave-one-subject-out cross-validation framework. The method improved signal-to-noise ratio by up to 9.65 dB, increased cross correlation with clean SKNA from 0.40 to 0.72, and restored burst-based SKNA features to near-clean discriminability (AUROC $\geq$ 0.96). Classification of baseline versus sympathetic stimulation (cognitive stress) conditions reached accuracies of 91--98\% across severe noise levels, comparable to clean data. These results demonstrate that deep learning--based reconstruction can preserve physiologically relevant sympathetic bursts during substantial EMG interference, enabling more robust SKNA monitoring in naturalistic, movement-rich environments.
Code (0)
등록된 구현이 없습니다.
Similar Papers 제목 키워드 기반
Orthogonal Features Based EEG Signals Denoising Using Fractional and Compressed One-Dimensional CNN AutoEncoder
This paper presents a fractional one-dimensional convolutional neural network (CNN) autoencoder for denoising the Electroencephalogram (EEG) signals which often get contaminated with noise during the recording process, m…
DenoisingEEGEEG DenoisingElectroencephalogram (EEG)TrustEMG-Net: Using Representation-Masking Transformer with U-Net for Surface Electromyography Enhancement
Surface electromyography (sEMG) is a widely employed bio-signal that captures human muscle activity via electrodes placed on the skin. Several studies have proposed methods to remove sEMG contaminants, as non-invasive me…
DenoisingEnhancing AI-Based ECG Delineation with Deep Learning Denoising Techniques
Evaluating canine electrocardiograms (ECGs) is challenging due to noise that can obscure clinically relevant cardiac electrical activity. Common sources of interference include respiration, muscle activity, poor lead con…
ECG DenoisingTowards Continuous Skin Sympathetic Nerve Activity Monitoring: Removing Muscle Noise
Continuous monitoring of non-invasive skin sympathetic nerve activity (SKNA) holds promise for understanding the sympathetic nervous system (SNS) dynamics in various physiological and pathological conditions. However, mu…
A novel convolutional neural network model to remove muscle artifacts from EEG
The recorded electroencephalography (EEG) signals are usually contaminated by many artifacts. In recent years, deep learning models have been used for denoising of electroencephalography (EEG) data and provided comparabl…
DenoisingEEGElectroencephalogram (EEG)Time Series+1