paper-with-me

홈 › Papers

Automated segmentation of an intensity calibration phantom in clinical CT images using a convolutional neural network

2020-12-21 · Keisuke Uemura, Yoshito Otake, Masaki Takao, Mazen Soufi, Akihiro Kawasaki, Nobuhiko Sugano, Yoshinobu Sato

Purpose: To apply a convolutional neural network (CNN) to develop a system that segments intensity calibration phantom regions in computed tomography (CT) images, and to test the system in a large cohort to evaluate its robustness. Methods: A total of 1040 cases (520 cases each from two institutions), in which an intensity calibration phantom (B-MAS200, Kyoto Kagaku, Kyoto, Japan) was used, were included herein. A training dataset was created by manually segmenting the regions of the phantom for 40 cases (20 cases each). Segmentation accuracy of the CNN model was assessed with the Dice coefficient and the average symmetric surface distance (ASD) through the 4-fold cross validation. Further, absolute differences of radiodensity values (in Hounsfield units: HU) were compared between manually segmented regions and automatically segmented regions. The system was tested on the remaining 1000 cases. For each institution, linear regression was applied to calculate coefficients for the correlation between radiodensity and the densities of the phantom. Results: After training, the median Dice coefficient was 0.977, and the median ASD was 0.116 mm. When segmented regions were compared between manual segmentation and automated segmentation, the median absolute difference was 0.114 HU. For the test cases, the median correlation coefficient was 0.9998 for one institution and was 0.9999 for the other, with a minimum value of 0.9863. Conclusions: The CNN model successfully segmented the calibration phantom's regions in the CT images with excellent accuracy, and the automated method was found to be at least equivalent to the conventional manual method. Future study should integrate the system by automatically segmenting the region of interest in bones such that the bone mineral density can be fully automatically quantified from CT images.

📄 PDF Abstract BibTeX arXiv:2012.11151

Code (1)

keisuke-uemura/CT-Intensity-Calibration-Phantom-Segmentation 공식 구현 tf

Tasks

Computed Tomography (CT)

Methods 이 논문이 사용한 방법론

Linear Regression Linear Regression is a method for modelling a relationship between a dependent variable and independent variables. These models can be fit with numerous approaches. The most…

Similar Papers 제목 키워드 기반

iPhantom: a framework for automated creation of individualized computational phantoms and its application to CT organ dosimetry

2020-08-20 · Wanyi Fu, Shobhit Sharma, Ehsan Abadi, Alexandros-Stavros Iliopoulos 외

Objective: This study aims to develop and validate a novel framework, iPhantom, for automated creation of patient-specific phantoms or digital-twins (DT) using patient medical images. The framework is applied to assess r…

Multi-atlas image registration of clinical data with automated quality assessment using ventricle segmentation

2019-07-01 · Florian Dubost, Marleen de Bruijne, Marco Nardin, Adrian V. Dalca 외

Registration is a core component of many imaging pipelines. In case of clinical scans, with lower resolution and sometimes substantial motion artifacts, registration can produce poor results. Visual assessment of registr…

Image Quality AssessmentImage Registration

Machine Learning based Analysis for Radiomics Features Robustness in Real-World Deployment Scenarios

2025-10-28 · Sarmad Ahmad Khan, Simon Bernatz, Zahra Moslehi, Florian Buettner arxiv

Radiomics-based machine learning models show promise for clinical decision support but are vulnerable to distribution shifts caused by variations in imaging protocols, positioning, and segmentation. This study systematic…

Deep intra-operative illumination calibration of hyperspectral cameras

2024-09-11 · Alexander Baumann, Leonardo Ayala, Alexander Studier-Fischer, Jan Sellner 외

Hyperspectral imaging (HSI) is emerging as a promising novel imaging modality with various potential surgical applications. Currently available cameras, however, suffer from poor integration into the clinical workflow be…

parameter estimationScene Segmentation

Uncertainty quantification for White Matter Hyperintensity segmentation detects silent failures and improves automated Fazekas quantification

2024-11-26 · Ben Philps, Maria del C. Valdes Hernandez, Chen Qin, Una Clancy 외

White Matter Hyperintensities (WMH) are key neuroradiological markers of small vessel disease present in brain MRI. Assessment of WMH is important in research and clinics. However, WMH are challenging to segment due to t…

SegmentationUncertainty Quantification