paper-with-me

Papers

Automatic Multi-Class Cardiovascular Magnetic Resonance Image Quality Assessment using Unsupervised Domain Adaptation in Spatial and Frequency Domains

2021-12-13 · Shahabedin Nabavi, Hossein Simchi, Mohsen Ebrahimi Moghaddam, Alejandro F. Frangi, Ahmad Ali Abin

Population imaging studies rely upon good quality medical imagery before downstream image quantification. This study provides an automated approach to assess image quality from cardiovascular magnetic resonance (CMR) imaging at scale. We identify four common CMR imaging artefacts, including respiratory motion, cardiac motion, Gibbs ringing, and aliasing. The model can deal with images acquired in different views, including two, three, and four-chamber long-axis and short-axis cine CMR images. Two deep learning-based models in spatial and frequency domains are proposed. Besides recognising these artefacts, the proposed models are suitable to the common challenges of not having access to data labels. An unsupervised domain adaptation method and a Fourier-based convolutional neural network are proposed to overcome these challenges. We show that the proposed models reliably allow for CMR image quality assessment. The accuracies obtained for the spatial model in supervised and weakly supervised learning are 99.41+0.24 and 96.37+0.66 for the UK Biobank dataset, respectively. Using unsupervised domain adaptation can somewhat overcome the challenge of not having access to the data labels. The maximum achieved domain gap coverage in unsupervised domain adaptation is 16.86%. Domain adaptation can significantly improve a 5-class classification task and deal with considerable domain shift without data labels. Increasing the speed of training and testing can be achieved with the proposed model in the frequency domain. The frequency-domain model can achieve the same accuracy yet 1.548 times faster than the spatial model. This model can also be used directly on k-space data, and there is no need for image reconstruction.

📄 PDF Abstract BibTeX arXiv:2112.06806

Code (0)

등록된 구현이 없습니다.

Tasks

Domain AdaptationImage Quality AssessmentImage ReconstructionUnsupervised Domain AdaptationWeakly-supervised Learning

Methods 이 논문이 사용한 방법론

SPEED The monocular depth estimation (MDE) is the task of estimating depth from a single frame. This information is an essential knowledge in many computer vision tasks such as scene…

Similar Papers 제목 키워드 기반

Automated Quality Controlled Analysis of 2D Phase Contrast Cardiovascular Magnetic Resonance Imaging

2022-09-28 · Emily Chan, Ciaran O'Hanlon, Carlota Asegurado Marquez, Marwenie Petalcorin 외

Flow analysis carried out using phase contrast cardiac magnetic resonance imaging (PC-CMR) enables the quantification of important parameters that are used in the assessment of cardiovascular function. An essential part …

Enhancing Cardiovascular Disease Prediction through Multi-Modal Self-Supervised Learning

2024-11-08 · Francesco Girlanda, Olga Demler, Bjoern Menze, Neda Davoudi

Accurate prediction of cardiovascular diseases remains imperative for early diagnosis and intervention, necessitating robust and precise predictive models. Recently, there has been a growing interest in multi-modal learn…

Contrastive LearningDisease PredictionSelf-Supervised Learning

Automated cardiovascular magnetic resonance image analysis with fully convolutional networks

2017-10-25 · Wenjia Bai, Matthew Sinclair, Giacomo Tarroni, Ozan Oktay 외

Cardiovascular magnetic resonance (CMR) imaging is a standard imaging modality for assessing cardiovascular diseases (CVDs), the leading cause of death globally. CMR enables accurate quantification of the cardiac chamber…

Groupwise Deformable Registration of Diffusion Tensor Cardiovascular Magnetic Resonance: Disentangling Diffusion Contrast, Respiratory and Cardiac Motions

2024-06-19 · Fanwen Wang, Yihao Luo, Ke Wen, Jiahao Huang 외

Diffusion tensor based cardiovascular magnetic resonance (DT-CMR) offers a non-invasive method to visualize the myocardial microstructure. With the assumption that the heart is stationary, frames are acquired with multip…

A Generalised Deep Meta-Learning Model for Automated Quality Control of Cardiovascular Magnetic Resonance Images

2023-03-23 · Shahabedin Nabavi, Hossein Simchi, Mohsen Ebrahimi Moghaddam, Ahmad Ali Abin 외

Background and Objectives: Cardiovascular magnetic resonance (CMR) imaging is a powerful modality in functional and anatomical assessment for various cardiovascular diseases. Sufficient image quality is essential to achi…

Domain AdaptationImage Quality AssessmentMeta-Learning