paper-with-me

홈 › Papers

Calibration-free B0 correction of EPI data using structured low rank matrix recovery

2018-04-20 · Arvind Balachandrasekaran, Merry Mani, Mathews Jacob

We introduce a structured low rank algorithm for the calibration-free compensation of field inhomogeneity artifacts in Echo Planar Imaging (EPI) MRI data. We acquire the data using two EPI readouts that differ in echo-time (TE). Using time segmentation, we reformulate the field inhomogeneity compensation problem as the recovery of an image time series from highly undersampled Fourier measurements. The temporal profile at each pixel is modeled as a single exponential, which is exploited to fill in the missing entries. We show that the exponential behavior at each pixel, along with the spatial smoothness of the exponential parameters, can be exploited to derive a 3D annihilation relation in the Fourier domain. This relation translates to a low rank property on a structured multi-fold Toeplitz matrix, whose entries correspond to the measured k-space samples. We introduce a fast two-step algorithm for the completion of the Toeplitz matrix from the available samples. In the first step, we estimate the null space vectors of the Toeplitz matrix using only its fully sampled rows. The null space is then used to estimate the signal subspace, which facilitates the efficient recovery of the time series of images. We finally demonstrate the proposed approach on spherical MR phantom data and human data and show that the artifacts are significantly reduced. The proposed approach could potentially be used to compensate for time varying field map variations in dynamic applications such as functional MRI.

📄 PDF Abstract BibTeX arXiv:1804.07436

Code (0)

등록된 구현이 없습니다.

Tasks

Time SeriesTime Series Analysis

Similar Papers 제목 키워드 기반

Navigator-free EPI Ghost Correction with Structured Low-Rank Matrix Models: New Theory and Methods

2017-08-16 · Rodrigo A. Lobos, Tae Hyung Kim, W. Scott Hoge, Justin P. Haldar

Structured low-rank matrix models have previously been introduced to enable calibrationless MR image reconstruction from sub-Nyquist data, and such ideas have recently been extended to enable navigator-free echo-planar i…

Image Reconstruction

Robust Autocalibrated Structured Low-Rank EPI Ghost Correction

2019-07-30 · Rodrigo A. Lobos, W. Scott Hoge, Ahsan Javed, Congyu Liao 외

Purpose: We propose and evaluate a new structured low-rank method for EPI ghost correction called Robust Autocalibrated LORAKS (RAC-LORAKS). The method can be used to suppress EPI ghosts arising from the differences betw…

Structured Low-Rank Algorithms: Theory, MR Applications, and Links to Machine Learning

2019-10-27 · Mathews Jacob, Merry P. Mani, Jong Chul Ye

In this survey, we provide a detailed review of recent advances in the recovery of continuous domain multidimensional signals from their few non-uniform (multichannel) measurements using structured low-rank matrix comple…

BIG-bench Machine Learningcompressed sensingLow-Rank Matrix CompletionMatrix Completion

Adaptive Signal Resuscitation: Channel-wise Post-Pruning Repair for Sparse Vision Networks

2026-05-20 · Qishi Zhan, Ziheng Chen, Minxuan Hu arxiv

One-shot magnitude pruning can cause severe accuracy collapse in the high-sparsity regime, even when the pruning mask preserves the largest weights. We argue that this failure reflects a granularity mismatch in post-prun…

GPTQ-intrinsic LoRA: A Near-optimal Algorithm for Low-precision Quantization with Low-rank Adaptation

2026-05-31 · Shihao Zhang, Rayan Saab arxiv

Post-training quantization is widely used for compressing large neural networks, but aggressive low-bit quantization can significantly degrade model quality. A common remedy is to augment the quantized weights with a low…