Calorimeter Shower Superresolution with Conditional Normalizing Flows: Implementation and Statistical Evaluation
In High Energy Physics, detailed calorimeter simulations and reconstructions are essential for accurate energy measurements and particle identification, but their high granularity makes them computationally expensive. Developing data-driven techniques capable of recovering fine-grained information from coarser readouts, a task known as calorimeter superresolution, offers a promising way to reduce both computational and hardware costs while preserving detector performance. This thesis investigates whether a generative model originally designed for fast simulation can be effectively applied to calorimeter superresolution. Specifically, the model proposed in arXiv:2308.11700 is re-implemented independently and trained on the CaloChallenge 2022 dataset based on the Geant4 Par04 calorimeter geometry. Finally, the model's performance is assessed through a rigorous statistical evaluation framework, following the methodology introduced in arXiv:2409.16336, to quantitatively test its ability to reproduce the reference distributions.
Code (0)
등록된 구현이 없습니다.
Similar Papers 제목 키워드 기반
Calorimeter shower superresolution
Calorimeter shower simulation is a major bottleneck in the Large Hadron Collider computational pipeline. There have been recent efforts to employ deep-generative surrogate models to overcome this challenge. However, many…
Super-ResolutionCaloFlow: Fast and Accurate Generation of Calorimeter Showers with Normalizing Flows
We introduce CaloFlow, a fast detector simulation framework based on normalizing flows. For the first time, we demonstrate that normalizing flows can reproduce many-channel calorimeter showers with extremely high fidelit…
Model SelectionConvolutional L2LFlows: Generating Accurate Showers in Highly Granular Calorimeters Using Convolutional Normalizing Flows
In the quest to build generative surrogate models as computationally efficient alternatives to rule-based simulations, the quality of the generated samples remains a crucial frontier. So far, normalizing flows have been …
CaloFlow II: Even Faster and Still Accurate Generation of Calorimeter Showers with Normalizing Flows
Recently, we introduced CaloFlow, a high-fidelity generative model for GEANT4 calorimeter shower emulation based on normalizing flows. Here, we present CaloFlow v2, an improvement on our original framework that speeds up…
Speech SynthesisCaloFlow for CaloChallenge Dataset 1
CaloFlow is a new and promising approach to fast calorimeter simulation based on normalizing flows. Applying CaloFlow to the photon and charged pion Geant4 showers of Dataset 1 of the Fast Calorimeter Simulation Challeng…