Centralised Multimode Power Oscillation Damping Controller for Photovoltaic Plants with Communication Delay Compensation
Low-frequency oscillations are an inherent phenomena in transmission networks and renewable energy plants should be configured to damp them. Commonly, a centralised controller is used in PV plants to coordinate PV generators via communication channels. However, the communication systems of PV plants introduce delays of a stochastic nature that degrade the performance of centralised control algorithms. Therefore, controllers for oscillation damping may not operate correctly unless the communication channel characteristics are not considered and compensated. In this paper, a centralised controller is proposed for the oscillation damping that uses a PV plant with all the realistic effects of communication channels taken into consideration. The communication channels are modelled based on measurements taken in a laboratory environment. The controller is designed to damp several modes of oscillation by using the open-loop phase shift compensation. Theoretical developments were validated in a laboratory using four converters acting as two PV inverters, a battery and a STATCOM. A real-time processing platform was used to implement the centralised controller and to deploy the communication infrastructure. Experimental results show the communication channels impose severe restrictions on the performance of centralised POD controllers, highlighting the importance of their accurate modelling and consideration during the controller design stage.
Code (0)
등록된 구현이 없습니다.
Similar Papers 제목 키워드 기반
Power Oscillation Damping Controllers for Grid-Forming Power Converters in Modern PowerSystems
Inter-area oscillations have been extensively studied in conventional power systems dominated by synchronous machines, as well as methods to mitigate them. Several publications have addressed Power Oscillation Damping (P…
Damping LFOs: Grid Following with Power Oscillation Damping vs. Grid Forming vs. PSS
Low-frequency oscillations (LFOs) present a significant challenge to the stability and reliability of power systems, especially in grids with a high penetration of renewable energy sources. Traditional grid-following (GF…
Measurement-Based Wide-Area Damping of Inter-Area Oscillations based on MIMO Identification
Interconnected power grid exhibits oscillatory response after a disturbance in the system. One such type of oscillations, the inter-area oscillations has the oscillation frequency in the range of 0.1 to 1 Hz. The damping…
Addressing intra-area oscillations and frequency stability after DC segmentation of a large AC power system
In the last decades, various events have shown that electromechanical oscillations are a major concern for large interconnected Alternating Current (AC) power systems. Segmentation of AC power systems with High Voltage D…
SegmentationCoordinated control in multi-terminal VSC-HVDC systems to improve transient stability: Impact on electromechanical-oscillation damping