Computerized Tomography with Total Variation and with Shearlets
To reduce the x-ray dose in computerized tomography (CT), many constrained optimization approaches have been proposed aiming at minimizing a regularizing function that measures lack of consistency with some prior knowledge about the object that is being imaged, subject to a (predetermined) level of consistency with the detected attenuation of x-rays. Proponents of the shearlet transform in the regularizing function claim that the reconstructions so obtained are better than those produced using TV for texture preservation (but may be worse for noise reduction). In this paper we report results related to this claim. In our reported experiments using simulated CT data collection of the head, reconstructions whose shearlet transform has a small $\ell_1$-norm are not more efficacious than reconstructions that have a small TV value. Our experiments for making such comparisons use the recently-developed superiorization methodology for both regularizing functions. Superiorization is an automated procedure for turning an iterative algorithm for producing images that satisfy a primary criterion (such as consistency with the observed measurements) into its superiorized version that will produce results that, according to the primary criterion are as good as those produced by the original algorithm, but in addition are superior to them according to a secondary (regularizing) criterion. The method presented for superiorization involving the $\ell_1$-norm of the shearlet transform is novel and is quite general: It can be used for any regularizing function that is defined as the $\ell_1$-norm of a transform specified by the application of a matrix. Because in the previous literature the split Bregman algorithm is used for similar purposes, a section is included comparing the results of the superiorization algorithm with the split Bregman algorithm.
Code (0)
등록된 구현이 없습니다.
Similar Papers 제목 키워드 기반
Radon-based Image Reconstruction for MPI using a continuously rotating FFL
Magnetic particle imaging is a relatively new tracer-based medical imaging technique exploiting the non-linear magnetization response of magnetic nanoparticles to changing magnetic fields. If the data are generated by us…
Image ReconstructionField-free Line Magnetic Particle Imaging: Radon-based Artifact Reduction with Motion Models
Magnetic particle imaging is a promising medical imaging technique. Applying changing magnetic fields to tracer material injected into the object under investigation results in a change in magnetization. Measurement of r…
Iterative Joint Ptychography-Tomography with Total Variation Regularization
In order to determine the 3D structure of a thick sample, researchers have recently combined ptychography (for high resolution) and tomography (for 3D imaging) in a single experiment. 2-step methods are usually adopted f…
A Nonlinear Weighted Total Variation Image Reconstruction Algorithm for Electrical Capacitance Tomography
A new iterative image reconstruction algorithm for electrical capacitance tomography (ECT) is proposed that is based on iterative soft thresholding of a total variation penalty and adaptive reweighted compressive sensing…
Compressive SensingImage ReconstructionSensitivityScale-Space Anisotropic Total Variation for Limited Angle Tomography
This paper addresses streak reduction in limited angle tomography. Although the iterative reweighted total variation (wTV) algorithm reduces small streaks well, it is rather inept at eliminating large ones since total va…