paper-with-me

홈 › Papers

Convolutional neural network based deep-learning architecture for intraprostatic tumour contouring on PSMA PET images in patients with primary prostate cancer

2020-08-07 · Dejan Kostyszyn, Tobias Fechter, Nico Bartl, Anca L. Grosu, Christian Gratzke, August Sigle, Michael Mix, Juri Ruf, Thomas F. Fassbender, Selina Kiefer, Alisa S. Bettermann, Nils H. Nicolay, Simon Spohn, Maria U. Kramer, Peter Bronsert, Hongqian Guo, Xuefeng Qiu, Feng Wang, Christoph Henkenberens, Rudolf A. Werner, Dimos Baltas, Philipp T. Meyer, Thorsten Derlin, Mengxia Chen, Constantinos Zamboglou

Accurate delineation of the intraprostatic gross tumour volume (GTV) is a prerequisite for treatment approaches in patients with primary prostate cancer (PCa). Prostate-specific membrane antigen positron emission tomography (PSMA-PET) may outperform MRI in GTV detection. However, visual GTV delineation underlies interobserver heterogeneity and is time consuming. The aim of this study was to develop a convolutional neural network (CNN) for automated segmentation of intraprostatic tumour (GTV-CNN) in PSMA-PET. Methods: The CNN (3D U-Net) was trained on [68Ga]PSMA-PET images of 152 patients from two different institutions and the training labels were generated manually using a validated technique. The CNN was tested on two independent internal (cohort 1: [68Ga]PSMA-PET, n=18 and cohort 2: [18F]PSMA-PET, n=19) and one external (cohort 3: [68Ga]PSMA-PET, n=20) test-datasets. Accordance between manual contours and GTV-CNN was assessed with Dice-S{\o}rensen coefficient (DSC). Sensitivity and specificity were calculated for the two internal test-datasets by using whole-mount histology. Results: Median DSCs for cohorts 1-3 were 0.84 (range: 0.32-0.95), 0.81 (range: 0.28-0.93) and 0.83 (range: 0.32-0.93), respectively. Sensitivities and specificities for GTV-CNN were comparable with manual expert contours: 0.98 and 0.76 (cohort 1) and 1 and 0.57 (cohort 2), respectively. Computation time was around 6 seconds for a standard dataset. Conclusion: The application of a CNN for automated contouring of intraprostatic GTV in [68Ga]PSMA- and [18F]PSMA-PET images resulted in a high concordance with expert contours and in high sensitivities and specificities in comparison with histology reference. This robust, accurate and fast technique may be implemented for treatment concepts in primary PCa. The trained model and the study's source code are available in an open source repository.

📄 PDF Abstract BibTeX arXiv:2008.03201

Code (0)

등록된 구현이 없습니다.

Tasks

Specificity

Similar Papers 제목 키워드 기반

When Two Tracers Disagree: An Investigation of Multimodal Fusion for Clinical PET/CT Segmentation

2026-08-19 · Jack A. Johnson, Bartłomiej W. Papież arxiv

PSMA and FDG PET/CT visualise complementary biological information in prostate cancer. Combining both tracers could capture heterogeneous tumour phenotypes that may be missed by either alone, yet there is no consensus on…

Lesion Segmentation

Tumour Ellipsification in Ultrasound Images for Treatment Prediction in Breast Cancer

2017-01-13 · Mehrdad J. Gangeh, Hamid. R. Tizhoosh, Kan Wu, Dun Huang 외

Recent advances in using quantitative ultrasound (QUS) methods have provided a promising framework to non-invasively and inexpensively monitor or predict the effectiveness of therapeutic cancer responses. One of the earl…

Segmentation of Prostate Tumour Volumes from PET Images is a Different Ball Game

2024-07-15 · Shrajan Bhandary, Dejan Kuhn, Zahra Babaiee, Tobias Fechter 외

Accurate segmentation of prostate tumours from PET images presents a formidable challenge in medical image analysis. Despite considerable work and improvement in delineating organs from CT and MR modalities, the existing…

Medical Image Analysis

Adaptive Voxel-Weighted Loss Using L1 Norms in Deep Neural Networks for Detection and Segmentation of Prostate Cancer Lesions in PET/CT Images

2025-02-04 · Obed Korshie Dzikunu, Shadab Ahamed, Amirhossein Toosi, Xiaoxiao Li 외

This study proposes a new loss function for deep neural networks, L1-weighted Dice Focal Loss (L1DFL), that leverages L1 norms for adaptive weighting of voxels based on their classification difficulty, towards automated …

Segmentation

Bridging MRI and PET physiology: Untangling complementarity through orthogonal representations

2026-04-08 · Sonja Adomeit, Kartikay Tehlan, Lukas Förner, Katharina Weisser 외 arxiv

Multimodal imaging analysis often relies on joint latent representations, yet these approaches rarely define what information is shared versus modality-specific. Clarifying this distinction is clinically relevant, as it …