Data-driven Under Frequency Load Shedding Using Reinforcement Learning
Underfrequency load shedding (UFLS) is a critical control strategy in power systems aimed at maintaining system stability and preventing blackouts during severe frequency drops. Traditional UFLS schemes often rely on predefined rules and thresholds, which may not adapt effectively to the dynamic and complex nature of modern power grids. Reinforcement learning (RL) methods have been proposed to effectively handle the UFLS problem. However, training these RL agents is computationally burdensome due to solving multiple differential equations at each step of training. This computational burden also limits the effectiveness of the RL agents for use in real-time. To reduce the computational burden, a machine learning (ML) classifier is trained to capture the frequency response of the system to various disturbances. The RL agent is then trained using the classifier, thus avoiding multiple computations during each step of agent training. Key features of this approach include reduced training time, as well as faster real-time application compared to other RL agents, and its potential to improve system resilience by minimizing the amount of load shed while effectively stabilizing the frequency. Comparative studies with conventional UFLS schemes demonstrate that the RL-based strategy achieves superior performance while significantly reducing the time required. Simulation results on the IEEE 68-bus system validate the performance of the proposed RL method.
Code (0)
등록된 구현이 없습니다.
Tasks
reinforcement-learningReinforcement LearningReinforcement Learning (RL)Similar Papers 제목 키워드 기반
A Data-driven Under Frequency Load Shedding Scheme in Power Systems
Under frequency load shedding (UFLS) constitutes the very last resort for preventing total blackouts and cascading events. Fluctuating operating conditions and weak resilience of the future grid require UFLS strategies a…
Proactive and Automatic Underfrequency Load Shedding via PMUs and Particle Filters
Underfrequency (UF) load shedding schemes are traditionally implemented in two ways: One approach is based on manual load shedding, with system operators requesting loads to be shed ahead of anticipated stressful operati…
Data-driven Estimation of Under Frequency Load Shedding after Outages in Small Power Systems
This paper presents a data-driven methodology for estimating Under Frequency Load Shedding (UFLS) in small power systems. UFLS plays a vital role in maintaining system stability by shedding load when the frequency drops …
SchedulingData-driven Coordinated AC/DC Control Strategy for Frequency Safety
With high penetrations of renewable energy and power electronics converters, less predictable operating conditions and strong uncertainties in under-frequency events pose challenges for emergency frequency control (EFC).…
Under Frequency Load Shedding based on PMU Estimates of Frequency and ROCOF
The paper describes a distributed under-frequency load shedding and load restoration scheme, that exploits frequency and Rate-of-Change-of-Frequency (ROCOF) measurements produced by Phasor Measurement Units (PMUs) as det…