paper-with-me

Papers

A Dataset-free Deep learning Method for Low-Dose CT Image Reconstruction

2022-05-01 · Qiaoqiao Ding, Hui Ji, Yuhui Quan, Xiaoqun Zhang

Low-dose CT (LDCT) imaging attracted a considerable interest for the reduction of the object's exposure to X-ray radiation. In recent years, supervised deep learning (DL) has been extensively studied for LDCT image reconstruction, which trains a network over a dataset containing many pairs of normal-dose and low-dose images. However, the challenge on collecting many such pairs in the clinical setup limits the application of such supervised-learning-based methods for LDCT image reconstruction in practice. Aiming at addressing the challenges raised by the collection of training dataset, this paper proposed a unsupervised deep learning method for LDCT image reconstruction, which does not require any external training data. The proposed method is built on a re-parametrization technique for Bayesian inference via deep network with random weights, combined with additional total variational~(TV) regularization. The experiments show that the proposed method noticeably outperforms existing dataset-free image reconstruction methods on the test data.

📄 PDF Abstract BibTeX arXiv:2205.00463

Code (0)

등록된 구현이 없습니다.

Tasks

Bayesian InferenceImage Reconstruction

Similar Papers 제목 키워드 기반

Double-Constraint Diffusion Model with Nuclear Regularization for Ultra-low-dose PET Reconstruction

2025-08-30 · Mengxiao Geng, Ran Hong, Bingxuan Li, Qiegen Liu arxiv

Ultra-low-dose positron emission tomography (PET) reconstruction holds significant potential for reducing patient radiation exposure and shortening examination times. However, it may also lead to increased noise and redu…

Information Extraction

Low-Dose CT Reconstruction Using Dataset-free Learning

2024-02-17 · Feng Wang, Renfang Wang, Hong Qiu

Low-Dose computer tomography (LDCT) is an ideal alternative to reduce radiation risk in clinical applications. Although supervised-deep-learning-based reconstruction methods have demonstrated superior performance compare…

CT Reconstruction

S3PET: Semi-supervised Standard-dose PET Image Reconstruction via Dose-aware Token Swap

2024-07-30 · Jiaqi Cui, Pinxian Zeng, Yuanyuan Xu, Xi Wu 외

To acquire high-quality positron emission tomography (PET) images while reducing the radiation tracer dose, numerous efforts have been devoted to reconstructing standard-dose PET (SPET) images from low-dose PET (LPET). H…

Image Reconstruction

Surrogate-free machine learning-based organ dose reconstruction for pediatric abdominal radiotherapy

2020-02-17 · M. Virgolin, Z. Wang, B. V. Balgobind, I. W. E. M. van Dijk 외

To study radiotherapy-related adverse effects, detailed dose information (3D distribution) is needed for accurate dose-effect modeling. For childhood cancer survivors who underwent radiotherapy in the pre-CT era, only 2D…

BIG-bench Machine Learning

AI-Enabled Ultra-Low-Dose CT Reconstruction

2021-06-17 · Weiwen Wu, Chuang Niu, Shadi Ebrahimian, Hengyong Yu 외

By the ALARA (As Low As Reasonably Achievable) principle, ultra-low-dose CT reconstruction is a holy grail to minimize cancer risks and genetic damages, especially for children. With the development of medical CT technol…

CT ReconstructionDiagnostic