Deep autofocus with cone-beam CT consistency constraint
High quality reconstruction with interventional C-arm cone-beam computed tomography (CBCT) requires exact geometry information. If the geometry information is corrupted, e. g., by unexpected patient or system movement, the measured signal is misplaced in the backprojection operation. With prolonged acquisition times of interventional C-arm CBCT the likelihood of rigid patient motion increases. To adapt the backprojection operation accordingly, a motion estimation strategy is necessary. Recently, a novel learning-based approach was proposed, capable of compensating motions within the acquisition plane. We extend this method by a CBCT consistency constraint, which was proven to be efficient for motions perpendicular to the acquisition plane. By the synergistic combination of these two measures, in and out-plane motion is well detectable, achieving an average artifact suppression of 93 [percent]. This outperforms the entropy-based state-of-the-art autofocus measure which achieves on average an artifact suppression of 54 [percent].
Code (0)
등록된 구현이 없습니다.
Tasks
Motion EstimationSimilar Papers 제목 키워드 기반
Image Quality Assessment for Rigid Motion Compensation
Diagnostic stroke imaging with C-arm cone-beam computed tomography (CBCT) enables reduction of time-to-therapy for endovascular procedures. However, the prolonged acquisition time compared to helical CT increases the lik…
DiagnosticImage Quality AssessmentMotion CompensationMotion EstimationLearned Cone-Beam CT Reconstruction Using Neural Ordinary Differential Equations
Learned iterative reconstruction algorithms for inverse problems offer the flexibility to combine analytical knowledge about the problem with modules learned from data. This way, they achieve high reconstruction performa…
CT ReconstructionGPUNumerical IntegrationACE-Net: AutofoCus-Enhanced Convolutional Network for Field Imperfection Estimation with application to high b-value spiral Diffusion MRI
Spatiotemporal magnetic field variations from B0-inhomogeneity and diffusion-encoding-induced eddy-currents can be detrimental to rapid image-encoding schemes such as spiral, EPI and 3D-cones, resulting in undesirable im…
Diffusion MRIImage ReconstructionDifferentiated Backprojection Domain Deep Learning for Conebeam Artifact Removal
Conebeam CT using a circular trajectory is quite often used for various applications due to its relative simple geometry. For conebeam geometry, Feldkamp, Davis and Kress algorithm is regarded as the standard reconstruct…
Deep LearningA New Weighting Scheme for Fan-beam and Circle Cone-beam CT Reconstructions
In this paper, we first present an arc based algorithm for fan-beam computed tomography (CT) reconstruction via applying Katsevich's helical CT formula to 2D fan-beam CT reconstruction. Then, we propose a new weighting f…
ARCComputed Tomography (CT)CT ReconstructionSSIM