Deep Learning How to Fit an Intravoxel Incoherent Motion Model to Diffusion-Weighted MRI

2019-02-28 · Sebastiano Barbieri, Oliver J. Gurney-Champion, Remy Klaassen, Harriet C. Thoeny

Purpose: This prospective clinical study assesses the feasibility of training a deep neural network (DNN) for intravoxel incoherent motion (IVIM) model fitting to diffusion-weighted magnetic resonance imaging (DW-MRI) data and evaluates its performance. Methods: In May 2011, ten male volunteers (age range: 29 to 53 years, mean: 37 years) underwent DW-MRI of the upper abdomen on 1.5T and 3.0T magnetic resonance scanners. Regions of interest in the left and right liver lobe, pancreas, spleen, renal cortex, and renal medulla were delineated independently by two readers. DNNs were trained for IVIM model fitting using these data; results were compared to least-squares and Bayesian approaches to IVIM fitting. Intraclass Correlation Coefficients (ICC) were used to assess consistency of measurements between readers. Intersubject variability was evaluated using Coefficients of Variation (CV). The fitting error was calculated based on simulated data and the average fitting time of each method was recorded. Results: DNNs were trained successfully for IVIM parameter estimation. This approach was associated with high consistency between the two readers (ICCs between 50 and 97%), low intersubject variability of estimated parameter values (CVs between 9.2 and 28.4), and the lowest error when compared with least-squares and Bayesian approaches. Fitting by DNNs was several orders of magnitude quicker than the other methods but the networks may need to be re-trained for different acquisition protocols or imaged anatomical regions. Conclusion: DNNs are recommended for accurate and robust IVIM model fitting to DW-MRI data. Suitable software is available at (1).

📄 PDF Abstract BibTeX arXiv:1903.00095

Code (2)

sebbarb/deep_ivim 공식 구현 pytorch
jamilabouhbouh/jb pytorch

Tasks

parameter estimation

Similar Papers 제목 키워드 기반

Implicit Modeling with Uncertainty Estimation for Intravoxel Incoherent Motion Imaging

2018-10-22 · Lin Zhang, Valery Vishnevskiy, Andras Jakab, Orcun Goksel

Intravoxel incoherent motion (IVIM) imaging allows contrast-agent free in vivo perfusion quantification with magnetic resonance imaging (MRI). However, its use is limited by typically low accuracy due to low signal-to-no…

parameter estimation

PIPPI2021: An Approach to Automated Diagnosis and Texture Analysis of the Fetal Liver & Placenta in Fetal Growth Restriction

2022-11-01 · Aya Mutaz Zeidan, Paula Ramirez Gilliland, Ashay Patel, Zhanchong Ou 외

Fetal growth restriction (FGR) is a prevalent pregnancy condition characterised by failure of the fetus to reach its genetically predetermined growth potential. We explore the application of model fitting techniques, lin…

regressionTexture Classification

Anatomically Guided Motion Correction for Placental IVIM Parameter Estimation with Accelerated Sampling Method

2025-03-21 · Mbaimou Auxence Ngremmadji, Freddy Odille, Charline Bertholdt, Marine Beaumont 외

Intravoxel incoherent motion (IVIM) is a diffusion-weighted magnetic resonance imaging (MRI) method that may be applied to the placenta to help diagnose abnormal pregnancies. IVIM requires prolonged scan times, followed …

parameter estimationSuper-Resolution

A Comprehensive Framework for Uncertainty Quantification of Voxel-wise Supervised Models in IVIM MRI

2025-08-06 · Nicola Casali, Alessandro Brusaferri, Giuseppe Baselli, Stefano Fumagalli 외 arxiv

Accurate estimation of intravoxel incoherent motion (IVIM) parameters from diffusion-weighted MRI remains challenging due to the ill-posed nature of the inverse problem and high sensitivity to noise, particularly in the …

Perfusion Imaging: A Data Assimilation Approach

2020-09-06 · Peirong Liu, Yueh Z. Lee, Stephen R. Aylward, Marc Niethammer

Perfusion imaging (PI) is clinically used to assess strokes and brain tumors. Commonly used PI approaches based on magnetic resonance imaging (MRI) or computed tomography (CT) measure the effect of a contrast agent movin…

Computed Tomography (CT)