Derivative-Based Mir Spectroscopy for Blood Glucose Estimation Using Pca-Driven Regression Models
In this study, we presented two innovative methods, which are Threshold-Based Derivative (TBD) and Adaptive Derivative Peak Detection(ADPD), that enhance the accuracy of Learning models for blood glucose estimation using Mid-Infrared (MIR) spectroscopy. In these presented methods, we have enhanced the model's accuracy by integrating absorbance data and its differentiation with critical points. Blood samples were characterized with Fourier Transform Infrared (FTIR) spectroscopy and advanced preprocessing steps. The learning models were Ridge Regression and Support Vector Regression(SVR) using Leave-One-out Cross-Validation. Results exhibited that TBD and ADPD significantly outperform basic used methods. For SVR, the TBD increased the r2 score by around 27%, and ADPD increased it by around 10%. these Ridge Regression values were between 36% and 24%. In addition, Results demonstrate that TBD and ADPD significantly outperform conventional methods, achieving lower error rates and improved clinical accuracy, validated through Clarke and Parkes Error Grid Analysis.
Code (0)
등록된 구현이 없습니다.
Tasks
regressionSimilar Papers 제목 키워드 기반
iGLU 1.0: An Accurate Non-Invasive Near-Infrared Dual Short Wavelengths Spectroscopy based Glucometer for Smart Healthcare
In the case of diabetes, fingertip pricking for a blood sample is inconvenient for glucose measurement. Invasive approaches like laboratory test and one-touch glucometer enhance the risk of blood-related infections. To m…
regressionReliable Noninvasive Glucose Sensing via CNN-Based Spectroscopy
In this study, we present a dual-modal AI framework based on short-wave infrared (SWIR) spectroscopy. The first modality employs a multi-wavelength SWIR imaging system coupled with convolutional neural networks (CNNs) to…
Fusion of Various Optimization Based Feature Smoothing Methods for Wearable and Non-invasive Blood Glucose Estimation
Recently, the wearable and non-invasive blood glucose estimation approach has been proposed. However, due to the unreliability of the acquisition device, the presence of the noise and the variations of the acquisition en…
A personalized model and optimization strategy for estimating blood glucose concentrations from sweat measurements
Background and objective: Diabetes is one of the four leading causes of death worldwide, necessitating daily blood glucose monitoring. While sweat offers a promising non-invasive alternative for glucose monitoring, its a…
Analysis of bio-electro-chemical signals from passive sweat-based wearable electro-impedance spectroscopy (EIS) towards assessing blood glucose modulations
There has been a recent tremendous interest in label-free detection of biomarkers which is a critical enabler of point-of-need diagnostics. A low-power, small form factor, multiplexed wearable system is proposed for cont…
Time Series Analysis