Developing Optimization-Based Inverter Models for Short Circuit Studies
As inverter-based generation becomes more common in distribution networks, it is important to create models for use in optimization-based problems that accurately represent their non-linear behavior when saturated. This work presents models for grid-following and grid-forming inverters, and demonstrates their use in optimization-based fault studies. The developed models are shown to provide results in line with experimental tests from literature; however, grid-forming inverter models fail to provide feasible solutions for certain fault types even when currents, voltages, and powers from the models seem reasonable. This work lays down the foundation for the development of relaxed models for both grid-following and grid-forming inverter models for use in optimization problems.
Code (0)
등록된 구현이 없습니다.
Methods 이 논문이 사용한 방법론
Similar Papers 제목 키워드 기반
Two-Stage Bidirectional Inverter Equivalent Circuit Model for Distribution Grid Steady-State Analysis and Optimization
This paper presents a \textit{physics-based} steady-state equivalent circuit model of a two-stage bidirectional inverter. These inverters connect distributed energy resources (DERs), such as photovoltaic (PV) and battery…
A Robust Solver for Phasor-Domain Short-Circuit Analysis with Inverter-Based Resources
The integration of Inverter-Based Resource (IBR) model into phasor-domain short circuit (SC) solvers challenges their numerical stability. To address the challenge, this paper proposes a solver that improves numerical st…
Dynamic State Estimation for Load Bus Protection on Inverter-Interfaced Microgrids
Inverter-interfaced microgrids results in challenges when designing protection systems. Traditional time-overcurrent, admittance, and differential protection methods are unsuitable on account of lack of fault current, ex…
State EstimationAn analysis of voltage source inverter switches fault classification using short time Fourier transform
The dependability of power electronics systems, such as three-phase inverters, is critical in a variety of applications. Different types of failures that occur in an inverter circuit might affect system operation and rai…
ClassificationEnsuring Disturbance Rejection Performance by Synthesizing Grid-Following and Grid-Forming Inverters in Power Systems
To satisfy dynamic requirements of power systems, it is imperative for grid-tied inverters to ensure good disturbance rejection performance (DRP) under variable grid conditions. This letter discovers and theoretically pr…