Drive and measurement electrode patterns for electrode impedance tomography (EIT) imaging of neural activity in peripheral nerve
Objective: To establish the performance of several drive and measurement patterns in EIT imaging of neural activity in peripheral nerve, which involves large impedance change in the nerve's anisotropic length axis. Approach: Eight drive and measurement electrode patterns are compared using a finite element (FE) four cylindrical shell model of a peripheral nerve and a 32 channel dual-ring nerve cuff. The central layer of the FE model contains impedance changes representative of neural activity of -0.3 in the length axis and -8.8 x 10-4 in the radial axis. Four of the electrode patterns generate longitudinal drive current, which runs perpendicular to the anisotropic axis. Main results: Transverse current patterns produce higher resolution than longitudinal patterns but are also more susceptible to noise and errors, and exhibit poorer sensitivity to impedance changes in central sample locations. Three of the four longitudinal current patterns considered can reconstruct fascicle level impedance changes with up to 0.2 mV noise and error, which corresponds to between -5.5 and +0.18 dB of the normalised signal standard deviation. Reducing the spacing between the two electrode rings in all longitudinal current patterns reduced the signal to error ratio across all depth locations of the sample. Significance: Electrode patterns which target the large impedance change in the anisotropic length axis can provide improved robustness against noise and errors, which is a critical step towards real time EIT imaging of neural activity in peripheral nerve.
Code (0)
등록된 구현이 없습니다.
Similar Papers 제목 키워드 기반
Predicting electrode array impedance after one month from cochlear implantation surgery
Sensorineural hearing loss can be treated using Cochlear implantation. After this surgery using the electrode array impedance measurements, we can check the stability of the impedance value and the dynamic range. Deterio…
speech-recognitionSpeech RecognitionOptimizing electrode positions in 2D Electrical Impedance Tomography using deep learning
Electrical Impedance Tomography (EIT) is a powerful tool for non-destructive evaluation, state estimation, and process tomography - among numerous other use cases. For these applications, and in order to reliably reconst…
State EstimationAnalysis of claims that the brain extracellular impedance is high and non-resistive
Numerous measurements in the brain of the impedance between two extracellular electrodes have shown that it is approximately resistive in the range of biological interest, $<10\,$kHz, and has a value close to that expect…
Neural networks for classification of strokes in electrical impedance tomography on a 3D head model
We consider the problem of the detection of brain hemorrhages from three dimensional (3D) electrical impedance tomography (EIT) measurements. This is a condition requiring urgent treatment for which EIT might provide a p…
AnatomyDesign and Analysis of Microfluidic Cell Counter using Spice Simulation
Microfluidic cytometers based on coulter principle have recently shown a great potential for point of care biosensors for medical diagnostics. In this study, the design of coulter based microfluidic cytometer is investig…