Dynamic Load Model for Data Centers with Pattern-Consistent Calibration
The rapid growth of data centers has made large electronic load (LEL) modeling increasingly important for power system analysis. Such loads are characterized by fast workload-driven variability and protection-driven disconnection and reconnection behavior that are not captured by conventional load models. Existing data center load modeling includes physics-based approaches, which provide interpretable structure for grid simulation, and data-driven approaches, which capture empirical workload variability from data. However, physics-based models are typically uncalibrated to facility-level operation, while trajectory alignment in data-driven methods often leads to overfitting and unrealistic dynamic behavior. To resolve these limitations, we design the framework to leverage both physics-based structure and data-driven adaptability. The physics-based structure is parameterized to enable data-driven pattern-consistent calibration from real operational data, supporting facility-level grid planning. We further show that trajectory-level alignment is limited for inherently stochastic data center loads. Therefore, we design the calibration to align temporal and statistical patterns using temporal contrastive learning (TCL). This calibration is performed locally at the facility, and only calibrated parameters are shared with utilities, preserving data privacy. The proposed load model is calibrated by real-world operational load data from the MIT Supercloud, ASU Sol, Blue Waters, and ASHRAE datasets. Then it is integrated into the ANDES platform and evaluated on the IEEE 39-bus, NPCC 140-bus, and WECC 179-bus systems. We find that interactions among LELs can fundamentally alter post-disturbance recovery behavior, producing compound disconnection-reconnection dynamics and delayed stabilization that are not captured by uncalibrated load models.
Code (0)
등록된 구현이 없습니다.
Tasks
Contrastive LearningSimilar Papers 제목 키워드 기반
Short-Term Load Forecasting for AI-Data Center
Recent research shows large-scale AI-centric data centers could experience rapid fluctuations in power demand due to varying computation loads, such as sudden spikes from inference or interruption of training large langu…
GPULoad ForecastingSparse-DySta: Sparsity-Aware Dynamic and Static Scheduling for Sparse Multi-DNN Workloads
Running multiple deep neural networks (DNNs) in parallel has become an emerging workload in both edge devices, such as mobile phones where multiple tasks serve a single user for daily activities, and data centers, where …
SchedulingGame-Theoretic Deep Reinforcement Learning to Minimize Carbon Emissions and Energy Costs for AI Inference Workloads in Geo-Distributed Data Centers
Data centers are increasingly using more energy due to the rise in Artificial Intelligence (AI) workloads, which negatively impacts the environment and raises operational costs. Reducing operating expenses and carbon emi…
Deep Reinforcement LearningThermal-aware Workload Distribution for Data Centers with Demand Variations
Thermal-aware workload distribution is a common approach in the literature for power consumption optimization in data centers. However, data centers also have other operational costs such as the cost of equipment mainten…
Model Predictive ControlCarbon Footprint Reduction for Sustainable Data Centers in Real-Time
As machine learning workloads significantly increase energy consumption, sustainable data centers with low carbon emissions are becoming a top priority for governments and corporations worldwide. This requires a paradigm…
Multi-agent Reinforcement Learning