paper-with-me

홈 › Papers

Evaluating the Impact of Pulse Oximetry Bias in Machine Learning under Counterfactual Thinking

2024-08-08 · Inês Martins, João Matos, Tiago Gonçalves, Leo A. Celi, A. Ian Wong, Jaime S. Cardoso

Algorithmic bias in healthcare mirrors existing data biases. However, the factors driving unfairness are not always known. Medical devices capture significant amounts of data but are prone to errors; for instance, pulse oximeters overestimate the arterial oxygen saturation of darker-skinned individuals, leading to worse outcomes. The impact of this bias in machine learning (ML) models remains unclear. This study addresses the technical challenges of quantifying the impact of medical device bias in downstream ML. Our experiments compare a "perfect world", without pulse oximetry bias, using SaO2 (blood-gas), to the "actual world", with biased measurements, using SpO2 (pulse oximetry). Under this counterfactual design, two models are trained with identical data, features, and settings, except for the method of measuring oxygen saturation: models using SaO2 are a "control" and models using SpO2 a "treatment". The blood-gas oximetry linked dataset was a suitable test-bed, containing 163,396 nearly-simultaneous SpO2 - SaO2 paired measurements, aligned with a wide array of clinical features and outcomes. We studied three classification tasks: in-hospital mortality, respiratory SOFA score in the next 24 hours, and SOFA score increase by two points. Models using SaO2 instead of SpO2 generally showed better performance. Patients with overestimation of O2 by pulse oximetry of > 3% had significant decreases in mortality prediction recall, from 0.63 to 0.59, P < 0.001. This mirrors clinical processes where biased pulse oximetry readings provide clinicians with false reassurance of patients' oxygen levels. A similar degradation happened in ML models, with pulse oximetry biases leading to more false negatives in predicting adverse outcomes.

📄 PDF Abstract BibTeX arXiv:2408.04396

Code (1)

inesamar/pulseoxbias 공식 구현

Tasks

counterfactualMortality Prediction

Similar Papers 제목 키워드 기반

Racial Disparities in Pulse Oximetry Cannot Be Fixed With Race-Based Correction

2022-10-10 · Neal Patwari, Di Huang, Kiki Bonetta-Misteli

Studies have shown pulse oximeter measurements of blood oxygenation have statistical bias that is a function of race, which results in higher rates of occult hypoxemia, i.e., missed detection of dangerously low oxygenati…

Learning Blood Oxygen from Respiration Signals

2021-01-01 · Hao He, Ying-Cong Chen, Yuan Yuan, Dina Katabi

Monitoring blood oxygen is critical in a variety of medical conditions including COVID-19. For almost a century, pulse oximetry has been the only noninvasive method for measuring blood oxygen. While highly useful, pulse …

Continuous SpO2 Monitoring Using Reflectance Pulse Oximetry at the Wrist and Upper Arm During Overnight Sleep Apnea Recordings

2025-05-27 · Karen Adam, Clémentine Aguet, Patrick Theurillat, Florent Baty 외

Sleep apnea (SA) is a chronic sleep-related disorder consisting of repetitive pauses or restrictions in airflow during sleep and is known to be a risk factor for cerebro- and cardiovascular disease. It is generally diagn…

Robust Modelling of Reflectance Pulse Oximetry for SpO$_2$ Estimation

2020-04-14 · Sricharan Vijayarangan, Prithvi Suresh, Preejith SP, Jayaraj Joseph 외

Continuous monitoring of blood oxygen saturation levels is vital for patients with pulmonary disorders. Traditionally, SpO$_2$ monitoring has been carried out using transmittance pulse oximeters due to its dependability.…

Machine learning for nocturnal diagnosis of chronic obstructive pulmonary disease using digital oximetry biomarkers

2020-12-10 · Jeremy Levy, Daniel Alvarez, Felix del Campo, Joachim A. Behar

Objective: Chronic obstructive pulmonary disease (COPD) is a highly prevalent chronic condition. COPD is a major source of morbidity, mortality and healthcare costs. Spirometry is the gold standard test for a definitive …

BIG-bench Machine LearningTime SeriesTime Series Analysis