paper-with-me

Papers

Fast Dynamic Perfusion and Angiography Reconstruction using an end-to-end 3D Convolutional Neural Network

2019-08-24 · Sahar Yousefi, Lydiane Hirschler, Merlijn van der Plas, Mohamed S. Elmahdy, Hessam Sokooti, Matthias Van Osch, Marius Staring

Hadamard time-encoded pseudo-continuous arterial spin labeling (te-pCASL) is a signal-to-noise ratio (SNR)-efficient MRI technique for acquiring dynamic pCASL signals that encodes the temporal information into the labeling according to a Hadamard matrix. In the decoding step, the contribution of each sub-bolus can be isolated resulting in dynamic perfusion scans. When acquiring te-ASL both with and without flow-crushing, the ASL-signal in the arteries can be isolated resulting in 4D-angiographic information. However, obtaining multi-timepoint perfusion and angiographic data requires two acquisitions. In this study, we propose a 3D Dense-Unet convolutional neural network with a multi-level loss function for reconstructing multi-timepoint perfusion and angiographic information from an interleaved $50\%$-sampled crushed and $50\%$-sampled non-crushed data, thereby negating the additional scan time. We present a framework to generate dynamic pCASL training and validation data, based on models of the intravascular and extravascular te-pCASL signals. The proposed network achieved SSIM values of $97.3 \pm 1.1$ and $96.2 \pm 11.1$ respectively for 4D perfusion and angiographic data reconstruction for 313 test data-sets.

📄 PDF Abstract BibTeX arXiv:1908.08947

Code (0)

등록된 구현이 없습니다.

Tasks

SSIM

Similar Papers 제목 키워드 기반

Synthetic Perfusion Maps: Imaging Perfusion Deficits in DSC-MRI with Deep Learning

2018-06-11 · Andreas Hess, Raphael Meier, Johannes Kaesmacher, Simon Jung 외

In this work, we present a novel convolutional neural net- work based method for perfusion map generation in dynamic suscepti- bility contrast-enhanced perfusion imaging. The proposed architecture is trained end-to-end a…

NIR ICG-Enhanced Fluorescence: A Quantitative Evaluation of Bowel Microperfusion and Its Relation to Central Perfusion in Colorectal Surgery

2024-03-04 · N. Depalma, S. D Ugo, F. Manoochehri, A. Libia 외

Background: To date, no standardized protocols nor a quantitative assessment of the near-infrared fluorescence angiography with indocyanine green (NIR-ICG) are available. The aim of this study was to evaluate the timing …

Decision MakingSpecificity

Accelerated Reconstruction of Perfusion-Weighted MRI Enforcing Jointly Local and Nonlocal Spatio-temporal Constraints

2017-08-25 · Cagdas Ulas, Christine Preibisch, Jonathan Sperl, Thomas Pyka 외

Perfusion-weighted magnetic resonance imaging (MRI) is an imaging technique that allows one to measure tissue perfusion in an organ of interest through the injection of an intravascular paramagnetic contrast agent (CA). …

parameter estimation

Improving Myocardium Segmentation in Cardiac CT Angiography using Spectral Information

2018-09-27 · Steffen Bruns, Jelmer M. Wolterink, Robbert W. van Hamersvelt, Majd Zreik 외

Accurate segmentation of the left ventricle myocardium in cardiac CT angiography (CCTA) is essential for e.g. the assessment of myocardial perfusion. Automatic deep learning methods for segmentation in CCTA might suffer …

Data AugmentationMyocardium SegmentationSegmentation

DSA-NRP: No-Reflow Prediction from Angiographic Perfusion Dynamics in Stroke EVT

2025-06-20 · Shreeram Athreya, Carlos Olivares, Ameera Ismail, Kambiz Nael 외

Following successful large-vessel recanalization via endovascular thrombectomy (EVT) for acute ischemic stroke (AIS), some patients experience a complication known as no-reflow, defined by persistent microvascular hypope…