paper-with-me

Papers

Generalized Pupil-Centric Imaging and Analytical Calibration for a Non-frontal Camera

2014-06-01 · CVPR 2014 6 · Avinash Kumar, Narendra Ahuja

We consider the problem of calibrating a small field of view central perspective non-frontal camera whose lens and sensor planes may not be parallel to each other. This can be due to manufacturing defects or intentional tilting. Thus, as such all cameras can be modeled as being non-frontal with varying degrees. There are two approaches to model non- frontal cameras. The first one based on rotation parameterization of sensor non-frontalness/tilt increases the number of calibration parameters, thus requiring heuristics to initialize a few calibration parameters for the final non-linear optimization step. Additionally, for this parameterization, while it has been shown that pupil-centric imaging model leads to more accurate rotation estimates than a thin-lens imaging model, it has only been developed for a single axis lens-sensor tilt. But, in real cameras we can have arbitrary tilt. The second approach based on decentering distortion modeling is approximate as it can only handle small tilts and cannot explicitly estimate the sensor tilt. In this paper, we focus on rotation based non-frontal camera calibration and address the aforementioned problems of over-parameterization and inadequacy of existing pupil-centric imaging model. We first derive a generalized pupil-centric imaging model for arbitrary axis lens-sensor tilt. We then derive an analytical solution, in this setting, for a subset of calibration parameters including sensor rotation angles as a function of center of radial distortion (CoD). A radial alignment based constraint is then proposed to computationally estimate CoD leveraging on the proposed analytical solution. Our analytical technique also estimates pupil-centric parameters of entrance pupil location and optical focal length, which have typically been done optically. Given these analytical and computational calibration parameter estimates, we initialize the non-linear calibration optimization for a set of synthetic and real data captured from a non-frontal camera and show reduced pixel re-projection and undistortion errors compared to state of the art techniques in rotation and decentering based approaches to non-frontal camera calibration.

📄 PDF Abstract BibTeX

Code (0)

등록된 구현이 없습니다.

Tasks

Camera Calibration

Similar Papers 제목 키워드 기반

Calibration of fisheye camera using entrance pupil

2019-07-03 · Peter Fasogbon, Emre Aksu

Most conventional camera calibration algorithms assume that the imaging device has a Single Viewpoint (SVP). This is not necessarily true for special imaging device such as fisheye lenses. As a consequence, the intrinsic…

Camera Calibration

On the Equivalence of Moving Entrance Pupil and Radial Distortion for Camera Calibration

2015-12-01 · ICCV 2015 12 · Avinash Kumar, Narendra Ahuja

Radial distortion for ordinary (non-fisheye) camera lenses has traditionally been modeled as an infinite series function of radial location of an image pixel from the image center. While there has been enough empirical e…

Camera Calibration

Teleidoscopic Imaging System for Microscale 3D Shape Reconstruction

2023-01-01 · CVPR 2023 1 · Ryo Kawahara, Meng-Yu Jennifer Kuo, Shohei Nobuhara

This paper proposes a practical method of microscale 3D shape capturing by a teleidoscopic imaging system. The main challenge in microscale 3D shape reconstruction is to capture the target from multiple viewpoints wi…

3D Shape Reconstruction

3D Gaze Estimation from 2D Pupil Positions on Monocular Head-Mounted Eye Trackers

2016-01-11 · Mohsen Mansouryar, Julian Steil, Yusuke Sugano, Andreas Bulling

3D gaze information is important for scene-centric attention analysis but accurate estimation and analysis of 3D gaze in real-world environments remains challenging. We present a novel 3D gaze estimation method for monoc…

Gaze Estimation

Center of circle after perspective transformation

2019-02-12 · Xi Wang, Albert Chern, Marc Alexa

Video-based glint-free eye tracking commonly estimates gaze direction based on the pupil center. The boundary of the pupil is fitted with an ellipse and the euclidean center of the ellipse in the image is taken as the ce…