paper-with-me

Papers

Ghost imaging-based Non-contact Heart Rate Detection

2024-06-04 · Jianming Yu, Yuchen He, Bin Li, Hui Chen, Huaibin Zheng, Jianbin Liu, Zhuo Xu

Remote heart rate measurement is an increasingly concerned research field, usually using remote photoplethysmography (rPPG) to collect heart rate information through video data collection. However, in certain specific scenarios (such as low light conditions, intense lighting, and non-line-of-sight situations), traditional imaging methods fail to capture image information effectively, that may lead to difficulty or inability in measuring heart rate. To address these limitations, this study proposes using ghost imaging as a substitute for traditional imaging in the aforementioned scenarios. The mean absolute error between experimental measurements and reference true values is 4.24 bpm.Additionally, the bucket signals obtained by the ghost imaging system can be directly processed using digital signal processing techniques, thereby enhancing personal privacy protection.

📄 PDF Abstract BibTeX arXiv:2406.02640

Code (0)

등록된 구현이 없습니다.

Similar Papers 제목 키워드 기반

Neutron Ghost Imaging

2019-11-13

Ghost imaging is demonstrated using a poly-energetic reactor source of thermal neutrons. The method presented enables position resolution to be incorporated, into a variety of neutron instruments that are not position re…

PositionSuper-Resolution

Compressed ghost edge imaging

2019-02-22

In this paper, we propose an advanced framework of ghost edge imaging, named compressed ghost edge imaging (CGEI). In the scheme, a set of structured speckle patterns with pixel shifting are illuminated on an unknown obj…

compressed sensingEdge DetectionObject

Universal computational thermal imaging overcoming the ghosting effect

2026-04-02 · Hongyi Xu, Du Wang, Chenjun Zhao, Jiashuo Chen 외 arxiv

Thermal imaging is crucial for night vision but fundamentally hampered by the ghosting effect, a loss of detailed texture in cluttered photon streams. While conventional ghosting mitigation has relied on data post-proces…

Time-Series U-Net with Recurrence for Noise-Robust Imaging Photoplethysmography

2025-03-21 · Vineet R. Shenoy, Shaoju Wu, Armand Comas, Tim K. Marks 외

Remote estimation of vital signs enables health monitoring for situations in which contact-based devices are either not available, too intrusive, or too expensive. In this paper, we present a modular, interpretable pipel…

Time Series

Rapid, remote and low-cost finger vasculature mapping for heart rate monitoring

2022-08-15 · Akhil Kallepalli, David B James, Mark A Richardson

Today's diagnostics include devices such as pulse oximeters, blood pressure monitors, and temperature measurements. These devices provide vital information to medical personnel when making treatment decisions. Drawing in…