paper-with-me

홈 › Papers

High-Resolution, Three-Dimensional Reconstruction of the Outflow Tract Demonstrates Segmental Differences in Cleared Eyes

2017-10-28

Purpose: The rate of conventional aqueous humor outflow is the highest nasally. We hypothesized that this is reflected in regionally different outflow structures and analyzed the entire limbus by high-resolution, full-thickness ribbon-scanning confocal microscopy (RSCM). Methods: We perfused pig eyes by anterior chamber cannulation with eight lectin-fluorophore conjugates, followed by optical clearance with benzyl alcohol benzyl benzoate (BABB). RSCM and an advanced analysis software (Imaris) were used to reconstruct a three-dimensional, whole-specimen rendering of the perilimbal outflow structures. We performed morphometric analyses of the outflow tract from the level of the trabecular meshwork (TM) to the scleral vascular plexus (SVP). Results: Except for pigmented structures, BABB cleared the entire eye. Rhodamine-conjugated Glycine max agglutinin (soybean, SBA) labeled the outflow tract evenly and retained fluorescence for months. RSCM produced terabyte-sized files allowing for in silico dissection of outflow tract vessel at a high resolution and in 3D. Networks of interconnected lumina were traced from the TM to downstream drainage structures. The collector channel (CC) volumes were ten times smaller than the receiving SVP vessels, the largest of which were in the inferior limbus. Proximal CC diameters were up to four times the size of distal diameters and more elliptical at their proximal ends. The largest CCs were found in the superonasal and inferonasal quadrants where the highest outflow occurs. Conclusions: RSCM of cleared eyes enabled high-resolution, volumetric analysis of the outflow tract. The proximal structures had greater diameters nasally while the SVP was larger in the inferior limbus.

📄 PDF Abstract BibTeX arXiv:1710.10508

Code (0)

등록된 구현이 없습니다.

Similar Papers 제목 키워드 기반

MVis-Fold: A Three-Dimensional Microvascular Structure Inference Model for Super-Resolution Ultrasound

2026-04-06 · Jincao Yao, Ke Zhang, Yahan Zhou, Jiafei Shen 외 arxiv

Super-resolution ultrasound (SRUS) technology has overcome the resolution limitations of conventional ultrasound, enabling micrometer-scale imaging of microvasculature. However, due to the nature of imaging principles, t…

High Resolution Surface Reconstruction of Cultural Heritage Objects Using Shape from Polarization Method

2024-06-21 · F. S. Mortazavi, M. Saadatseresht

Nowadays, three-dimensional reconstruction is used in various fields like computer vision, computer graphics, mixed reality and digital twin. The three-dimensional reconstruction of cultural heritage objects is one of th…

Mixed RealitySurface Reconstruction

Surface Normal Reconstruction Using Polarization-Unet

2024-06-21 · F. S. Mortazavi, S. Dajkhosh, M. Saadatseresht

Today, three-dimensional reconstruction of objects has many applications in various fields, and therefore, choosing a suitable method for high resolution three-dimensional reconstruction is an important issue and display…

Super Resolution Based on Deep Operator Networks

2024-10-11 · Siyuan Yang

We use Deep Operator Networks (DeepONets) to perform super-resolution reconstruction of the solutions of two types of partial differential equations and compare the model predictions with the results obtained using conve…

Operator learningSuper-Resolution

Subarcsecond Submillimeter Imaging of the Ultracompact HII Region G5.89-0.39

2015-03-27

We present the first subarcsecond submillimeter images of the enigmatic ultracompact HII region (UCHII) G5.89-0.39. Observed with the SMA, the 875 micron continuum emission exhibits a shell-like morphology similar to lon…