paper-with-me

Papers

Image-based immersed boundary model of the aortic root

2017-05-04 · Ali Hasan, Ebrahim M. Kolahdouz, Andinet Enquobahrie, Thomas G. Caranasos, John P. Vavalle, Boyce E. Griffith

Each year, approximately 300,000 heart valve repair or replacement procedures are performed worldwide, including approximately 70,000 aortic valve replacement surgeries in the United States alone. This paper describes progress in constructing anatomically and physiologically realistic immersed boundary (IB) models of the dynamics of the aortic root and ascending aorta. This work builds on earlier IB models of fluid-structure interaction (FSI) in the aortic root, which previously achieved realistic hemodynamics over multiple cardiac cycles, but which also were limited to simplified aortic geometries and idealized descriptions of the biomechanics of the aortic valve cusps. By contrast, the model described herein uses an anatomical geometry reconstructed from patient-specific computed tomography angiography (CTA) data, and employs a description of the elasticity of the aortic valve leaflets based on a fiber-reinforced constitutive model fit to experimental tensile test data. Numerical tests show that the model is able to resolve the leaflet biomechanics in diastole and early systole at practical grid spacings. The model is also used to examine differences in the mechanics and fluid dynamics yielded by fresh valve leaflets and glutaraldehyde-fixed leaflets similar to those used in bioprosthetic heart valves. Although there are large differences in the leaflet deformations during diastole, the differences in the open configurations of the valve models are relatively small, and nearly identical hemodynamics are obtained in all cases considered.

📄 PDF Abstract BibTeX arXiv:1705.04279

Code (0)

등록된 구현이 없습니다.

Similar Papers 제목 키워드 기반

Aortic root landmark localization with optimal transport loss for heatmap regression

2024-07-06 · Tsuyoshi Ishizone, Masaki Miyasaka, Sae Ochi, Norio Tada 외

Anatomical landmark localization is gaining attention to ease the burden on physicians. Focusing on aortic root landmark localization, the three hinge points of the aortic valve can reduce the burden by automatically det…

regression

A Design-Based Model of the Aortic Valve for Fluid-Structure Interaction

2020-10-05 · Alexander D. Kaiser, Rohan Shad, William Hiesinger, Alison L. Marsden

This paper presents a new method for modeling the mechanics of the aortic valve, and simulates its interaction with blood. As much as possible, the model construction is based on first principles, but such that the model…

Automatic Aortic Valve Pathology Detection from 3-Chamber Cine MRI with Spatio-Temporal Attention Maps

2023-04-12 · Y. On, K. Vimalesvaran, C. Galazis, S. Zaman 외

The assessment of aortic valve pathology using magnetic resonance imaging (MRI) typically relies on blood velocity estimates acquired using phase contrast (PC) MRI. However, abnormalities in blood flow through the aortic…

3D ClassificationClassification

Generative 3D Cardiac Shape Modelling for In-Silico Trials

2024-09-24 · Andrei Gasparovici, Alex Serban

We propose a deep learning method to model and generate synthetic aortic shapes based on representing shapes as the zero-level set of a neural signed distance field, conditioned by a family of trainable embedding vectors…

Towards Patient-Specific Surgical Planning for Bicuspid Aortic Valve Repair: Fully Automated Segmentation of the Aortic Valve in 4D CT

2025-02-13 · Zaiyang Guo, Ningjun J Dong, Harold Litt, Natalie Yushkevich 외

The bicuspid aortic valve (BAV) is the most prevalent congenital heart defect and may require surgery for complications such as stenosis, regurgitation, and aortopathy. BAV repair surgery is effective but challenging due…

Computed Tomography (CT)SegmentationTemporal Sequences