paper-with-me

Papers

Image Quality Assessment for Magnetic Resonance Imaging

2022-03-15 · Segrey Kastryulin, Jamil Zakirov, Nicola Pezzotti, Dmitry V. Dylov

Image quality assessment (IQA) algorithms aim to reproduce the human's perception of the image quality. The growing popularity of image enhancement, generation, and recovery models instigated the development of many methods to assess their performance. However, most IQA solutions are designed to predict image quality in the general domain, with the applicability to specific areas, such as medical imaging, remaining questionable. Moreover, the selection of these IQA metrics for a specific task typically involves intentionally induced distortions, such as manually added noise or artificial blurring; yet, the chosen metrics are then used to judge the output of real-life computer vision models. In this work, we aspire to fill these gaps by carrying out the most extensive IQA evaluation study for Magnetic Resonance Imaging (MRI) to date (14,700 subjective scores). We use outputs of neural network models trained to solve problems relevant to MRI, including image reconstruction in the scan acceleration, motion correction, and denoising. Our emphasis is on reflecting the radiologist's perception of the reconstructed images, gauging the most diagnostically influential criteria for the quality of MRI scans: signal-to-noise ratio, contrast-to-noise ratio, and the presence of artifacts. Seven trained radiologists assess these distorted images, with their verdicts then correlated with 35 different image quality metrics (full-reference, no-reference, and distribution-based metrics considered). The top performers -- DISTS, HaarPSI, VSI, and FID-VGG16 -- are found to be efficient across three proposed quality criteria, for all considered anatomies and the target tasks.

📄 PDF Abstract BibTeX arXiv:2203.07809

Code (1)

photosynthesis-team/piq 공식 구현 pytorch

Tasks

DenoisingImage EnhancementImage Quality AssessmentImage Reconstruction

Similar Papers 제목 키워드 기반

Engineering AI Tools for Systematic and Scalable Quality Assessment in Magnetic Resonance Imaging

2021-12-02 · Yukai Zou, Ikbeom Jang

A desire to achieve large medical imaging datasets keeps increasing as machine learning algorithms, parallel computing, and hardware technology evolve. Accordingly, there is a growing demand in pooling data from multiple…

Diagnostic Image Quality Assessment and Classification in Medical Imaging: Opportunities and Challenges

2019-12-05 · Jeffrey Ma, Ukash Nakarmi, Cedric Yue Sik Kin, Christopher Sandino 외

Magnetic Resonance Imaging (MRI) suffers from several artifacts, the most common of which are motion artifacts. These artifacts often yield images that are of non-diagnostic quality. To detect such artifacts, images are …

DiagnosticGeneral ClassificationImage Quality Assessment

A Generalised Deep Meta-Learning Model for Automated Quality Control of Cardiovascular Magnetic Resonance Images

2023-03-23 · Shahabedin Nabavi, Hossein Simchi, Mohsen Ebrahimi Moghaddam, Ahmad Ali Abin 외

Background and Objectives: Cardiovascular magnetic resonance (CMR) imaging is a powerful modality in functional and anatomical assessment for various cardiovascular diseases. Sufficient image quality is essential to achi…

Domain AdaptationImage Quality AssessmentMeta-Learning

Statistical Distance-Guided Unsupervised Domain Adaptation for Automated Multi-Class Cardiovascular Magnetic Resonance Image Quality Assessment

2024-08-31 · Shahabedin Nabavi, Kian Anvari Hamedani, Mohsen Ebrahimi Moghaddam, Ahmad Ali Abin 외

This study proposes an attention-based statistical distance-guided unsupervised domain adaptation model for multi-class cardiovascular magnetic resonance (CMR) image quality assessment. The proposed model consists of a f…

Domain AdaptationImage Quality AssessmentUnsupervised Domain Adaptation

Off-resonance artifact correction for magnetic resonance imaging: a review

2022-05-02 · Melissa W. Haskell, Jon-Fredrik Nielsen, Douglas C. Noll

In magnetic resonance imaging (MRI), inhomogeneity in the main magnetic field used for imaging, referred to as off-resonance, can lead to image artifacts ranging from mild to severe depending on the application. Off-reso…