Improving Axial Resolution of Optical Resolution Photoacoustic Microscopy with Advanced Frequency Domain Eigenspace Based Minimum Variance Beamforming Method

2023-09-18 · Yu-Hsiang Yu, Meng-Lin Li

Optical resolution photoacoustic microscopy (OR-PAM) leverages optical focusing and acoustic detection for microscopic optical absorption imaging. Intrinsically it owns high optical lateral resolution and poor acoustic axial resolution. Such anisometric resolution hinders good 3-D visualization; thus 2-D maximum amplitude projection images are commonly presented in the literature. Since its axial resolution is limited by the bandwidth of acoustic detectors, ultrahigh frequency, and wideband detectors with Wiener deconvolution have been proposed to address this issue. Nonetheless, they also introduce other issues such as severe high-frequency attenuation and limited imaging depth. In this work, we view axial resolution improvement as an axial signal reconstruction problem, and the axial resolution degradation is caused by axial sidelobe interference. We propose an advanced frequency-domain eigenspace-based minimum variance (F-EIBMV) beamforming technique to suppress axial sidelobe interference and noises. This method can simultaneously enhance the axial resolution and contrast of OR-PAM. For a 25-MHz OR-PAM system, the full-width at half-maximum of an axial point spread function decreased significantly from 69.3 $\mu$m to 16.89 $\mu$m, indicating a significant improvement in axial resolution.

📄 PDF Abstract BibTeX arXiv:2309.09409

Code (0)

등록된 구현이 없습니다.

Similar Papers 제목 키워드 기반

Direct 3D information fusion for depth of field enhancement in optical-resolution photoacoustic microscopy

2022-11-24 · Xianlin Song, Sihang Li, Zhuangzhuang Wang

As an important branch of photoacoustic microscopy, optical-resolution photoacoustic microscopy suffers from limited depth of field due to the strongly focused laser beam. In this work, a 3D information fusion algorithm …

Super-resolution photoacoustic microscopy using blind structured illumination

2016-12-21 · optica 2016 12 · Todd W. Murray

We present a method for enhancing the spatial resolution of optical-absorption-based photoacoustic imaging through or within highly scattering media. The optical speckle pattern that emerges as light propagates through …

ObjectSuper-Resolution

Improving axial resolution in SIM using deep learning

2020-09-04 · Miguel Boland, Edward A. K. Cohen, Seth Flaxman, Mark A. A. Neil

Structured Illumination Microscopy is a widespread methodology to image live and fixed biological structures smaller than the diffraction limits of conventional optical microscopy. Using recent advances in image up-scali…

Deep Learning

Computational TIRF enables optical sectioning beyond the evanescent field for widefield fluorescence microscopy

2025-11-10 · Qiushi Li, Celi Lou, Yanfang Cheng, Bilang Gong 외 arxiv

The resolving ability of widefield fluorescence microscopy is fundamentally limited by out-of-focus background owing to its low axial resolution, particularly for densely labeled biological samples. Although total intern…

Dc-EEMF: Pushing depth-of-field limit of photoacoustic microscopy via decision-level constrained learning

2025-05-29 · Wangting Zhou, Jiangshan He, Tong Cai, Lin Wang 외

Photoacoustic microscopy holds the potential to measure biomarkers' structural and functional status without labels, which significantly aids in comprehending pathophysiological conditions in biomedical research. However…

Multi Focus Image Fusion