Interpretation of Confocal ISO 21073: 2019 confocal microscopes: Optical data of fluorescence confocal microscopes for biological imaging- Recommended Methodology for Quality Control
The performance of a confocal imaging system may be no better than a general-purpose widefield system if it is not properly maintained or quality controlled. The publication of ISO 21073, 'Confocal microscopes- Optical data of fluorescence confocal microscopes for biological imaging', set a standard for the minimal Quality Control (QC) that should be performed for Confocal Microscopes. Here we describe methodology for performing the QC requirements to satisfy ISO 21073, as well as suggesting other QC methods that should be performed to obtain a minimum level of information about the microscope system.
Code (0)
등록된 구현이 없습니다.
Similar Papers 제목 키워드 기반
The Quest for Early Detection of Retinal Disease: 3D CycleGAN-based Translation of Optical Coherence Tomography into Confocal Microscopy
Optical coherence tomography (OCT) and confocal microscopy are pivotal in retinal imaging, offering distinct advantages and limitations. In vivo OCT offers rapid, non-invasive imaging but can suffer from clarity issues a…
DiagnosticOCT2Confocal: 3D CycleGAN based Translation of Retinal OCT Images to Confocal Microscopy
Optical coherence tomography (OCT) and confocal microscopy are pivotal in retinal imaging, each presenting unique benefits and limitations. In-vivo OCT offers rapid, non-invasive imaging but can be hampered by clarity is…
DiagnosticImage Super Resolution via Bilinear Pooling: Application to Confocal Endomicroscopy
Recent developments in image acquisition literature have miniaturized the confocal laser endomicroscopes to improve usability and flexibility of the apparatus in actual clinical settings. However, miniaturized devices co…
Image Super-ResolutionSSIMSuper-ResolutionAxially-shifted pattern illumination for macroscale turbidity suppression and virtual volumetric confocal imaging without axial scanning
Structured illumination has been widely used for optical sectioning and 3D surface recovery. In a typical implementation, multiple images under non-uniform pattern illumination are used to recover a single object section…
High Resolution, Deep Imaging Using Confocal Time-of-flight Diffuse Optical Tomography
Light scattering by tissue severely limits how deep beneath the surface one can image, and the spatial resolution one can obtain from these images. Diffuse optical tomography (DOT) is one of the most powerful techniques …
Vocal Bursts Intensity Prediction