2024-10-17 · Jaesang Park, Alireza Askarian, Srinivasa Salapaka

As inverter-based loads and energy sources become increasingly prevalent, accurate estimation of line impedance between inverters and the grid is essential for optimizing performance and enhancing control strategies. This paper presents a non-invasive method for estimating output-line impedance using measurements local to the inverter. It provides a specific method for signal conditioning of signals measured at the inverter, which makes the measured data better suited to estimation algorithms. An algorithm based on the Variable Direction Forgetting Recursive Least Squares (VDF-RLS) method is introduced, which leverages these conditioned signals for precise impedance estimation. The signal conditioning process transforms measurements into the direct-quadrature (dq) coordinate frame, where the rotating frame frequency is determined to facilitate a simpler and more accurate estimation. This frequency is implemented using a secondary Phase-Locked Loop (PLL) to attenuate grid voltage measurement variations. By isolating the variation-sensitive q-axis and relying solely on the less sensitive d-axis, the method further minimizes the impact of variations. The VDF-RLS estimation method achieves rapid adaptation while ensuring stability in the absence of persistent excitation by selectively discarding outdated data during updates. Proposed conditioning and estimation methods are non-invasive; estimations are solely done using measured outputs, and no signal is injected into the power network. Simulation results demonstrate a significant improvement in impedance estimation stability, particularly in low-excitation conditions, where the VDF-RLS method achieves more than three time lower error compared to existing approaches such as constant forgetting RLS and the Kalman filter.

📄 PDF Abstract BibTeX arXiv:2410.14077

Code (0)

등록된 구현이 없습니다.

Similar Papers 제목 키워드 기반

Class E/EF Inductive Power Transfer to Achieve Stable Output under Variable Low Coupling

2025-02-19 · Yifan Zhao, Mowei Lu, Heyuan Li, Zhenbin Zhang 외

This paper develops an inductive power transfer(IPT)system with stable output power based on a Class E/EF inverter. Load-independent design of Class E/EF inverter has recently attracted widespread interest. However, appl…

Advanced Control Strategy to Compensate Power Sharing Error and DC Circulating Current in Parallel Single-Phase Inverters

2024-12-20 · Quoc Nam Trinh, Bang Nguyen, Rob Hovsapian

This paper proposes an advanced control strategy to eliminate both current sharing error and DC circulating current caused by line impedance mismatched and measurement errors in islanded AC microgrid system. The proposed…

The Impact of Three-phase Impedances on the Stability of DER systems

2021-07-12 · Jaimie Swartz, Alexandra von Meier

In this work we explore impedance-based interactions that arise when inverter-connected distributed energy resources (DERs) inject real and reactive power to regulate voltage and power flows on three-phase unbalanced dis…

A Virtual Admittance-Based Fault Current Limiting Method for Grid-Forming Inverters

2025-05-15 · Zaid Ibn Mahmood, Hantao Cui, Ying Zhang

Inverter-based resources (IBRs) are a key component in the ongoing modernization of power systems, with grid-forming (GFM) inverters playing a central role. Effective fault current limiting is a major challenge to modern…

Extended Impedance Modal Analysis of Internal Dynamics in Grid-Following Inverters

2025-03-02 · Le Zheng, Jiajie Zheng, Lei Chen, Chongru Liu

As the penetration of Grid-Following inverters (GFL) in power systems continues to increase, the dynamic characteristics of power systems undergo significant transformations. Recently, modal analysis based on the impedan…