paper-with-me

Papers

Joint Multi-Echo/Respiratory Motion-Resolved Compressed Sensing Reconstruction of Free-Breathing Non-Cartesian Abdominal MRI

2023-03-27 · Youngwook Kee, MungSoo Kang, Seongho Jeong, Gerald Behr

We propose a novel respiratory motion-resolved MR image reconstruction method that jointly treats multi-echo k-space raw data. Continuously acquired non-Cartesian multi-echo/multi-coil k-space data with free breathing are sorted/binned into the motion states from end-expiratory to end-inspiratory phases based on a respiratory motion signal. Temporal total variation applied to the motion state dimension of each echo is then coupled in the $\ell_2$ sense for joint reconstruction of the multiple echoes. Reconstructed source images of the proposed method are compared with conventional echo-by-echo motion-resolved reconstruction, and R2* of the proposed and echo-by-echo methods are compared with respect to a clinical reference. We demonstrate that inconsistency between echoes is successfully suppressed in the proposed joint reconstruction method, producing high-quality source images and R2* measurements compared to clinical reference.

📄 PDF Abstract BibTeX arXiv:2303.15144

Code (0)

등록된 구현이 없습니다.

Tasks

compressed sensingImage Reconstruction

Similar Papers 제목 키워드 기반

A Novel Low-Rank Tensor Method for Undersampling Artifact Removal in Respiratory Motion-Resolved Multi-Echo 3D Cones MRI

2023-05-01 · Seongho Jeong, MungSoo Kang, Gerald Behr, Heechul Jeong 외

We propose a novel low-rank tensor method for respiratory motion-resolved multi-echo image reconstruction. The key idea is to construct a 3-way image tensor (space $\times$ echo $\times$ motion state) from the convention…

compressed sensingImage Reconstruction

ICoNIK: Generating Respiratory-Resolved Abdominal MR Reconstructions Using Neural Implicit Representations in k-Space

2023-08-17 · Veronika Spieker, Wenqi Huang, Hannah Eichhorn, Jonathan Stelter 외

Motion-resolved reconstruction for abdominal magnetic resonance imaging (MRI) remains a challenge due to the trade-off between residual motion blurring caused by discretized motion states and undersampling artefacts. In …

Radar-Based Respiratory Measurement of a Rhesus Monkey by Suppressing Nonperiodic Body Motion Components

2023-06-29 · Takuya Sakamoto, Daisuke Sanematsu, Itsuki Iwata, Toshiki Minami 외

We propose a method to measure the respiration of a rhesus monkey using a millimeter-wave radar system with an antenna array. Unlike humans, small animals are generally restless and hyperactive in nature, and suppression…

MoRe-3DGSMR: Motion-resolved reconstruction framework for free-breathing pulmonary MRI based on 3D Gaussian representation

2025-05-08 · Tengya Peng, Ruyi Zha, Qing Zou

This study presents an unsupervised, motion-resolved reconstruction framework for high-resolution, free-breathing pulmonary magnetic resonance imaging (MRI), utilizing a three-dimensional Gaussian representation (3DGS). …

3DGSMRI Reconstruction

Noncontact Respiratory Measurement for Multiple People at Arbitrary Locations Using Array Radar and Respiratory-Space Clustering

2021-01-29 · Takato Koda, Takuya Sakamoto, Shigeaki Okumura, Hirofumi Taki

We developed a noncontact measurement system for monitoring the respiration of multiple people using millimeter-wave array radar. To separate the radar echoes of multiple people, conventional techniques cluster the radar…

Clustering