Limitations on concentration measurements and gradient discerning times in cellular systems
This work reports on two results. At first we revisit the Berg and Purcell calculation that provides a lower bound to the error in concentration measurement by cells, by considering the realistic case when the cell starts measuring the moment it comes in contact with the chemoattractants, instead of measuring after equilibrating with the chemotactic concentration as done in the classic Berg and Purcell paper. We find that the error in concentration measurement is still the same as evaluated by Berg and Purcell. We next derive a lower bound on measurement time below which it is not possible for the cell to discern extra-cellular chemotactic gradients through spatial sensing mechanisms. This bound is independent of diffusion rate and concentration of the chemoattracts and is instead set by detachment rate of ligands from the cell receptors. The result could help explain experimental observations.
Code (0)
등록된 구현이 없습니다.
Methods 이 논문이 사용한 방법론
Similar Papers 제목 키워드 기반
Role of spatial averaging in multicellular gradient sensing
Gradient sensing underlies important biological processes including morphogenesis, polarization, and cell migration. The precision of gradient sensing increases with the length of a detector (a cell or group of cells) in…
Optimal Sample Complexity of Subgradient Descent for Amplitude Flow via Non-Lipschitz Matrix Concentration
We consider the problem of recovering a real-valued $n$-dimensional signal from $m$ phaseless, linear measurements and analyze the amplitude-based non-smooth least squares objective. We establish local convergence of sub…
Predicting concentration changes via discrete sampling
To successfully navigate chemical gradients, microorganisms need to predict how the ligand concentration changes in space. Due to their limited size, they do not take a spatial derivative over their body length but rathe…
NavigateTradeoffs in concentration sensing in dynamic environments
When cells measure concentrations of chemical signals, they may average multiple measurements over time in order to reduce noise in their measurements. However, when cells are in a environment that changes over time, pas…
Conversion of the chemical concentration of odorous mixtures into odour concentration and odour intensity: a comparison of methods
Continuous odour measurements both of emissions as well as ambient concentrations are seldom realised, mainly because of their high costs. They are therefore often substituted by concentration measurements of odorous sub…