paper-with-me

홈 › Papers

Metal Artifact Reduction in 2D CT Images with Self-supervised Cross-domain Learning

2021-09-28 · Lequan Yu, Zhicheng Zhang, Xiaomeng Li, Hongyi Ren, Wei Zhao, Lei Xing

The presence of metallic implants often introduces severe metal artifacts in the X-ray CT images, which could adversely influence clinical diagnosis or dose calculation in radiation therapy. In this work, we present a novel deep-learning-based approach for metal artifact reduction (MAR). In order to alleviate the need for anatomically identical CT image pairs (i.e., metal artifact-corrupted CT image and metal artifact-free CT image) for network learning, we propose a self-supervised cross-domain learning framework. Specifically, we train a neural network to restore the metal trace region values in the given metal-free sinogram, where the metal trace is identified by the forward projection of metal masks. We then design a novel FBP reconstruction loss to encourage the network to generate more perfect completion results and a residual-learning-based image refinement module to reduce the secondary artifacts in the reconstructed CT images. To preserve the fine structure details and fidelity of the final MAR image, instead of directly adopting CNN-refined images as output, we incorporate the metal trace replacement into our framework and replace the metal-affected projections of the original sinogram with the prior sinogram generated by the forward projection of the CNN output. We then use the filtered backward projection (FBP) algorithms for final MAR image reconstruction. We conduct an extensive evaluation on simulated and real artifact data to show the effectiveness of our design. Our method produces superior MAR results and outperforms other compelling methods. We also demonstrate the potential of our framework for other organ sites.

📄 PDF Abstract BibTeX arXiv:2109.13483

Code (0)

등록된 구현이 없습니다.

Tasks

Image ReconstructionMetal Artifact Reduction

Similar Papers 제목 키워드 기반

ADN: Artifact Disentanglement Network for Unsupervised Metal Artifact Reduction

2019-08-03 · Haofu Liao, Wei-An Lin, S. Kevin Zhou, Jiebo Luo

Current deep neural network based approaches to computed tomography (CT) metal artifact reduction (MAR) are supervised methods that rely on synthesized metal artifacts for training. However, as synthesized data may not a…

Computed Tomography (CT)DisentanglementImage-to-Image TranslationMedical Image Generation+2

Three-dimensional Generative Adversarial Nets for Unsupervised Metal Artifact Reduction

2019-11-19 · Megumi Nakao, Keiho Imanishi, Nobuhiro Ueda, Yuichiro Imai 외

The reduction of metal artifacts in computed tomography (CT) images, specifically for strong artifacts generated from multiple metal objects, is a challenging issue in medical imaging research. Although there have been s…

Computed Tomography (CT)Metal Artifact ReductionTranslation

Dense Transformer based Enhanced Coding Network for Unsupervised Metal Artifact Reduction

2023-07-24 · Wangduo Xie, Matthew B. Blaschko

CT images corrupted by metal artifacts have serious negative effects on clinical diagnosis. Considering the difficulty of collecting paired data with ground truth in clinical settings, unsupervised methods for metal arti…

DisentanglementMetal Artifact Reduction

U-DuDoNet: Unpaired dual-domain network for CT metal artifact reduction

2021-03-08 · Yuanyuan Lyu, Jiajun Fu, Cheng Peng, S. Kevin Zhou

Recently, both supervised and unsupervised deep learning methods have been widely applied on the CT metal artifact reduction (MAR) task. Supervised methods such as Dual Domain Network (Du-DoNet) work well on simulation d…

DisentanglementMetal Artifact Reduction

MARformer: An Efficient Metal Artifact Reduction Transformer for Dental CBCT Images

2023-11-16 · Yuxuan Shi, Jun Xu, Dinggang Shen

Cone Beam Computed Tomography (CBCT) plays a key role in dental diagnosis and surgery. However, the metal teeth implants could bring annoying metal artifacts during the CBCT imaging process, interfering diagnosis and dow…

Metal Artifact Reduction