MGMAR: Metal-Guided Metal Artifact Reduction for X-ray Computed Tomography
An X-ray computed tomography (CT), metal artifact reduction (MAR) remains a major challenge because metallic implants violate standard CT forward-model assumptions, producing severe streaking and shadowing artifacts that degrade diagnostic quality. We propose MGMAR, a metal-guided MAR method that explicitly leverages metal-related information throughout the reconstruction pipeline. MGMAR first generates a high-quality prior image by training a conditioned implicit neural representation (INR) using metal-unaffected projections, and then incorporates this prior into a normalized MAR (NMAR) framework for projection completion. To improve robustness under severe metal corruption, we pretrain the encoder-conditioned INR on paired metal-corrupted and artifact-free CT images, thereby embedding data-driven prior knowledge into the INR parameter space. This prior-embedded initialization reduces sensitivity to random initialization and accelerates convergence during measurement-specific refinement. The encoder takes a metal-corrupted reconstruction together with a recursively constructed metal artifact image, enabling the latent field to capture metal-dependent global artifact patterns. After projection completion using the INR prior, we further suppress residual artifacts using a metal-conditioned correction network, where the metal mask modulates intermediate features via adaptive instance normalization to target metal-dependent secondary artifacts while preserving anatomical structures. Experiments on the public AAPM-MAR benchmark demonstrate that MGMAR achieves state-of-the-art performance, attaining an average final score of 0.89 on 29 clinical test cases.
Code (0)
등록된 구현이 없습니다.
Similar Papers 제목 키워드 기반
AS-Mamba: Asymmetric Self-Guided Mamba Decoupled Iterative Network for Metal Artifact Reduction
Metal artifact significantly degrades Computed Tomography (CT) image quality, impeding accurate clinical diagnosis. However, existing deep learning approaches, such as CNN and Transformer, often fail to explicitly captur…
Metal Artifact Reduction in Cone-Beam X-Ray CT via Ray Profile Correction
In computed tomography (CT), metal implants increase the inconsistencies between the measured data and the linear attenuation assumption made by analytic CT reconstruction algorithms. The inconsistencies give rise to dar…
Computed Tomography (CT)CT ReconstructionDiagnosticMetal Artifact ReductionThree-dimensional Generative Adversarial Nets for Unsupervised Metal Artifact Reduction
The reduction of metal artifacts in computed tomography (CT) images, specifically for strong artifacts generated from multiple metal objects, is a challenging issue in medical imaging research. Although there have been s…
Computed Tomography (CT)Metal Artifact ReductionTranslationEncoding Metal Mask Projection for Metal Artifact Reduction in Computed Tomography
Metal artifact reduction (MAR) in computed tomography (CT) is a notoriously challenging task because the artifacts are structured and non-local in the image domain. However, they are inherently local in the sinogram doma…
Computed Tomography (CT)Metal Artifact ReductionA Metal Artifact Reduction Scheme For Accurate Iterative Dual-Energy CT Algorithms
CT images have been used to generate radiation therapy treatment plans for more than two decades. Dual-energy CT (DECT) has shown high accuracy in estimating electronic density or proton stopping-power maps used in treat…
DiagnosticMetal Artifact Reduction