paper-with-me

홈 › Papers

Model-based free-breathing cardiac MRI reconstruction using deep learned \& STORM priors: MoDL-STORM

2018-07-10 · Sampurna Biswas, Hemant K. Aggarwal, Sunrita Poddar, Mathews Jacob

We introduce a model-based reconstruction framework with deep learned (DL) and smoothness regularization on manifolds (STORM) priors to recover free breathing and ungated (FBU) cardiac MRI from highly undersampled measurements. The DL priors enable us to exploit the local correlations, while the STORM prior enables us to make use of the extensive non-local similarities that are subject dependent. We introduce a novel model-based formulation that allows the seamless integration of deep learning methods with available prior information, which current deep learning algorithms are not capable of. The experimental results demonstrate the preliminary potential of this work in accelerating FBU cardiac MRI.

📄 PDF Abstract BibTeX arXiv:1807.03845

Code (0)

등록된 구현이 없습니다.

Tasks

Deep LearningMRI Reconstruction

Similar Papers 제목 키워드 기반

Free-breathing and ungated cardiac cine using navigator-less spiral SToRM

2019-01-16 · Abdul Haseeb Ahmed, Yasir Mohsin, Ruixi Zhou, Yang Yang 외

Purpose: To develop a free-breathing and ungated cardiac MRI scheme using an iterative kernel low-rank algorithm and self-gated spiral sequence. Methods: The data were acquired continuously over 8-16 seconds per slice wi…

Free-breathing cardiac MRI using bandlimited manifold modelling

2018-02-24 · Sunrita Poddar, Yasir Mohsin, Deidra Ansah, Bijoy Thattaliyath 외

We introduce a novel bandlimited manifold framework and an algorithm to recover freebreathing and ungated cardiac MR images from highly undersampled measurements. The image frames in the free breathing and ungated datase…

Free-breathing Cardiovascular MRI Using a Plug-and-Play Method with Learned Denoiser

2020-02-08 · Sizhuo Liu, Edward Reehorst, Philip Schniter, Rizwan Ahmad

Cardiac magnetic resonance imaging (CMR) is a noninvasive imaging modality that provides a comprehensive evaluation of the cardiovascular system. The clinical utility of CMR is hampered by long acquisition times, however…

compressed sensingDenoising

Piecewise Dynamic Diffusion Regularization for Reconstruction of Cardiac Cine MRI

2026-07-03 · Florian Fürnrohr, Reinhard Heckel arxiv

Real-time cardiac cine MRI enables visualization of the beating heart during free breathing, but severe undersampling and motion make reconstruction highly challenging. A central challenge for reconstruction is incorpora…

Motion-Robust Deep Reconstruction for Free-Breathing Cardiac Cine MRI

2026-05-20 · Mahmut Yurt, Kanghyun Ryu, Zhitao Li, Xucheng Zhu 외 arxiv

Conventional cardiac cine MRI relies on breath-hold Cartesian acquisitions, which are vulnerable to motion artifacts and can be uncomfortable or infeasible, particularly for pediatric and other noncompliant patients who …