Novel Phase Detector Measurement Procedure Using Quasi-Synchronized RF Generator

2024-02-07 · V. A. Pulido, F. Cabrera-Almeida, P. Quintana-Morales, E. Mendieta-Otero

This paper presents a new procedure for phase detector measurements that allows the use of generators that share a 10 MHz reference oscillator but do not synchronize in phase, in other words, quasi-synchronized RF generators. The objectives are taking advantage of the benefits of using two generators but recovering lower-cost generators that have worse synchronization performance and opening the door to the possibility of using a very simple control element based in Arduino Uno and cheaper instruments. The new procedure is characterized by continuously alternating calibration and measurement sequences to make up for the phase drift of quasisynchronized generators and guarantee a maximum phase error specification (+-1 grade in this paper). Data acquisition has been divided in two stages: measurement of detector curves without phase reference (in-phase and phase-shifted) and measurement of reference data. All the data is later combined to obtain correctly referenced in-phase detector curves. The technique can be reproduced with other equivalent instrumentation. The novel procedure that allows compensation for errors (amplitude, phase shift, mismatching, etc.) is detailed, and its relation to the required measurement accuracy is amply discussed. The proposed technique is applied to characterize a phase detector based on in-phase and phase-shifted multiplication from 3 to 8 GHz with 1 GHz step. Measurements have a final maximum error of +-2 grade for both frequency and calibrated input power, according to the accuracy specifications of the VNA used to calibrate the signal distribution network, added to the +-1 grade specified in this new procedure.

📄 PDF Abstract BibTeX arXiv:2402.04831

Code (0)

등록된 구현이 없습니다.

Similar Papers 제목 키워드 기반

A Topological Lowpass Filter for Quasiperiodic Signals

2016-06-28 · Michael Robinson

This article presents a two-stage topological algorithm for recovering an estimate of a quasiperiodic function from a set of noisy measurements. The first stage of the algorithm is a topological phase estimator, which de…

360° phase detector cell for measurement systems based on switched dual multipliers

2024-04-19 · Baltasar Pérez, Víctor A. Araña, Javier Perez-Mato, Francisco Cabrera

This letter presents a 360{\deg} phase detector cell for performing phase-shift measurements on multiple output systems. An analog phase detector, capable of detecting a maximum range of {\pm}90{\deg}, has been used to p…

A New Channel Model for OAM Wireless Communication at 5.8 and 28 GHz

2024-09-06 · Runyu Lyu, Wenchi Cheng, Muyao Wang, Fan Qin 외

Orbital angular momentum (OAM) in electromagnetic (EM) waves can significantly enhance spectrum efficiency in wireless communications without requiring additional power, time, or frequency resources. Different OAM modes …

High-Sensitivity and Compact Time-domain Soil Moisture Sensor Using Dispersive Phase Shifter for Complex Permittivity Measurement

2024-08-20 · Rasool Keshavarz, Negin Shariati

This paper presents a Time-Domain Transmissometry Soil Moisture Sensor (TDT-SMS) using a Dispersive Phase Shifter (DPS), consisting of an interdigital capacitor that is loaded with a stacked 4-turn Complementary Spiral R…

Sensitivity

Imaging the Developing Heart: Synchronized Timelapse Microscopy During Developmental Changes

2018-02-15

How do you use imaging to analyse the development of the heart, which not only changes shape but also undergoes constant, high-speed, quasi-periodic changes? We have integrated ideas from prospective and retrospective op…