paper-with-me

Papers

On the Use of Singular Value Decomposition as a Clutter Filter for Ultrasound Flow Imaging

2023-04-25 · Kai Riemer, Marcelo Lerendegui, Matthieu Toulemonde, Jiaqi Zhu, Christopher Dunsby, Peter D. Weinberg, Meng-Xing Tang

Filtering based on Singular Value Decomposition (SVD) provides substantial separation of clutter, flow and noise in high frame rate ultrasound flow imaging. The use of SVD as a clutter filter has greatly improved techniques such as vector flow imaging, functional ultrasound and super-resolution ultrasound localization microscopy. The removal of clutter and noise relies on the assumption that tissue, flow and noise are each represented by different subsets of singular values, so that their signals are uncorrelated and lay on orthogonal sub-spaces. This assumption fails in the presence of tissue motion, for near-wall or microvascular flow, and can be influenced by an incorrect choice of singular value thresholds. Consequently, separation of flow, clutter and noise is imperfect, which can lead to image artefacts not present in the original data. Temporal and spatial fluctuation in intensity are the commonest artefacts, which vary in appearance and strengths. Ghosting and splitting artefacts are observed in the microvasculature where the flow signal is sparsely distributed. Singular value threshold selection, tissue motion, frame rate, flow signal amplitude and acquisition length affect the prevalence of these artefacts. Understanding what causes artefacts due to SVD clutter and noise removal is necessary for their interpretation.

📄 PDF Abstract BibTeX arXiv:2304.12783

Code (0)

등록된 구현이 없습니다.

Tasks

Super-Resolution

Similar Papers 제목 키워드 기반

Unsupervised Unfolded rPCA (U2-rPCA): Deep Interpretable Clutter Filtering for Ultrasound Microvascular Imaging

2025-10-01 · Huaying Li, Chuling Ye, Manfei Liao, Xiaobo Qu 외 arxiv

High-sensitivity clutter filtering is a fundamental step in ultrasound microvascular imaging. Singular value decomposition (SVD) and robust principal component analysis (rPCA) are the main clutter filtering strategies. H…

Joint Blind Deconvolution and Robust Principal Component Analysis for Blood Flow Estimation in Medical Ultrasound Imaging

2020-07-10 · Duong-Hung Pham, Adrian Basarab, Ilyess Zemmoura, Jean-Pierre Remenieras 외

This paper addresses the problem of high-resolution Doppler blood flow estimation from an ultrafast sequence of ultrasound images. Formulating the separation of clutter and blood components as an inverse problem has been…

Clutter Mitigation for Joint RadCom Systems Based On Spatial Modulation

2021-05-16 · Jifa Zhang

Joint radar and communication (RadCom) systems have been proposed to integrate radar and communication into one platform and achieve spectrum sharing in recent years. However, the joint RadCom systems cause the clutter m…

4D-UNet improves clutter rejection in human transcranial contrast enhanced ultrasound

2026-02-20 · Tristan Beruard, Armand Delbos, Arthur Chavignon, Maxence Reberol 외 arxiv

Transcranial ultrasound imaging is limited by high skull absorption, limiting vascular imaging to only the largest vessels. Traditional clutter filters struggle with low signal-to-noise ratio (SNR) ultrasound datasets, w…

CRAP Part II: Clutter Removal with Continuous Acquisitions Under Phase Noise

2024-02-19 · Marcus Henninger, Silvio Mandelli, Artjom Grudnitsky, Stephan ten Brink

The mitigation of clutter is an important research branch in Integrated Sensing and Communication (ISAC), one of the emerging technologies of future cellular networks. In this work, we extend our previously introduced me…