Optical detection of Aflatoxins B in grained almonds using fluorescence spectroscopy and machine learning algorithms
Aflatoxins are fungal metabolites extensively produced by many different fungal species that may contaminate a wide range of agricultural food products. They have been studied extensively because of being associated with various chronic and acute diseases especially immunosuppression and cancer and their presence in food is strictly monitored and regulated worldwide. Aflatoxin detection and measurement relies mainly on chemical methods usually based on chromatography approaches, and recently developed immunochemical based assays that have advantages but also limitations, since these are expensive and destructive techniques. Nondestructive, optical approaches are recently being developed to assess presence of contamination in a cost and time effective way, maintaining acceptable accuracy and reproducibility. In this paper are presented the results obtained with a simple portable device for nondestructive detection of aflatoxins in almonds. The presented approach is based on the analysis of fluorescence spectra of slurried almonds under 375 nm wavelength excitation. Experiments were conducted with almonds contaminated in the range of 2.7-320.2 ng/g total aflatoxins B (AFB1 + AFB2) as determined by HPLC/FLD. After applying pre-processing steps, spectral analysis was carried out by a binary classification model based on SVM algorithm. A majority vote procedure was then performed on the classification results. In this way we could achieve, as best result, a classification accuracy of 94% (and false negative rate 5%) with a threshold set at 6.4 ng/g. These results illustrate the feasibility of such an approach in the great challenge of aflatoxin detection for food and feed safety.
Code (0)
등록된 구현이 없습니다.
Tasks
Binary ClassificationSimilar Papers 제목 키워드 기반
Miniature fluorescence sensor for quantitative detection of brain tumour
Fluorescence-guided surgery has emerged as a vital tool for tumour resection procedures. As well as intraoperative tumour visualisation, 5-ALA-induced PpIX provides an avenue for quantitative tumour identification based …
SpecificityDesign and Validation of a Low-Cost Smartphone Based Fluorescence Detection Platform Compared with Conventional Microplate Readers
A low cost fluorescence-based optical system is developed for detecting the presence of certain microorganisms and molecules within a diluted sample. A specifically designed device setup compatible with conventional 96 w…
Supercritical angle microscopy and spectroscopy
Fluorescence detection, either involving propagating or near-field emission, is widely being used in spectroscopy, sensing and microscopy. Total internal reflection fluorescence (TIRF) confines fluorescence excitation by…
Fluorescence molecular optomic signatures improve identification of tumors in head and neck specimens
In this study, a radiomics approach was extended to optical fluorescence molecular imaging data for tissue classification, termed 'optomics'. Fluorescence molecular imaging is emerging for precise surgical guidance durin…
Computational TIRF enables optical sectioning beyond the evanescent field for widefield fluorescence microscopy
The resolving ability of widefield fluorescence microscopy is fundamentally limited by out-of-focus background owing to its low axial resolution, particularly for densely labeled biological samples. Although total intern…