Physically-Grounded Manifold Projection Model for Generalizable Metal Artifact Reduction in Dental CBCT
Metal artifacts in Dental CBCT severely obscure anatomical structures, hindering diagnosis. Current deep learning for Metal Artifact Reduction (MAR) faces limitations: supervised methods suffer from spectral blurring due to "regression-to-the-mean", while unsupervised ones risk structural hallucinations. Denoising Diffusion Models (DDPMs) offer realism but rely on slow, stochastic iterative sampling, unsuitable for clinical use. To resolve this, we propose the Physically-Grounded Manifold Projection (PGMP) framework. First, our Anatomically-Adaptive Physics Simulation (AAPS) pipeline synthesizes high-fidelity training pairs via Monte Carlo spectral modeling and patient-specific digital twins, bridging the synthetic-to-real gap. Second, our DMP-Former adapts the Direct x-Prediction paradigm, reformulating restoration as a deterministic manifold projection to recover clean anatomy in a single forward pass, eliminating stochastic sampling. Finally, a Semantic-Structural Alignment (SSA) module anchors the solution using priors from medical foundation models (MedDINOv3), ensuring clinical plausibility. Experiments on synthetic and multi-center clinical datasets show PGMP outperforms state-of-the-art methods on unseen anatomy, setting new benchmarks in efficiency and diagnostic reliability. Code and data: https://github.com/ricoleehduu/PGMP.
Code (0)
등록된 구현이 없습니다.
Similar Papers 제목 키워드 기반
Deep Sinogram Completion with Image Prior for Metal Artifact Reduction in CT Images
Computed tomography (CT) has been widely used for medical diagnosis, assessment, and therapy planning and guidance. In reality, CT images may be affected adversely in the presence of metallic objects, which could lead to…
Computed Tomography (CT)Image GenerationMedical DiagnosisMetal Artifact ReductionLumiTex: Towards High-Fidelity PBR Texture Generation with Illumination Context
Physically-based rendering (PBR) provides a principled standard for realistic material-lighting interactions in computer graphics. Despite recent advances in generating PBR textures, existing methods fail to address two …
Deep learning based projection domain metal segmentation for metal artifact reduction in cone beam computed tomography
Metal artifact correction is a challenging problem in cone beam computed tomography (CBCT) scanning. Metal implants inserted into the anatomy cause severe artifacts in reconstructed images. Widely used inpainting-based m…
AnatomyDeep LearningMetal Artifact ReductionSegmentationProjection Inpainting Using Partial Convolution for Metal Artifact Reduction
In computer tomography, due to the presence of metal implants in the patient body, reconstructed images will suffer from metal artifacts. In order to reduce metal artifacts, metals are typically removed in projection ima…
Metal Artifact ReductionvalidGenerative Mask Pyramid Network for CT/CBCT Metal Artifact Reduction with Joint Projection-Sinogram Correction
A conventional approach to computed tomography (CT) or cone beam CT (CBCT) metal artifact reduction is to replace the X-ray projection data within the metal trace with synthesized data. However, existing projection or si…
Computed Tomography (CT)Metal Artifact Reduction