paper-with-me

홈 › Papers

Physically-Grounded Manifold Projection Model for Generalizable Metal Artifact Reduction in Dental CBCT

2025-12-30 · Zhi Li, Yaqi Wang, Bingtao Ma, Yifan Zhang, Huiyu Zhou, Shuai Wang arxiv

Metal artifacts in Dental CBCT severely obscure anatomical structures, hindering diagnosis. Current deep learning for Metal Artifact Reduction (MAR) faces limitations: supervised methods suffer from spectral blurring due to "regression-to-the-mean", while unsupervised ones risk structural hallucinations. Denoising Diffusion Models (DDPMs) offer realism but rely on slow, stochastic iterative sampling, unsuitable for clinical use. To resolve this, we propose the Physically-Grounded Manifold Projection (PGMP) framework. First, our Anatomically-Adaptive Physics Simulation (AAPS) pipeline synthesizes high-fidelity training pairs via Monte Carlo spectral modeling and patient-specific digital twins, bridging the synthetic-to-real gap. Second, our DMP-Former adapts the Direct x-Prediction paradigm, reformulating restoration as a deterministic manifold projection to recover clean anatomy in a single forward pass, eliminating stochastic sampling. Finally, a Semantic-Structural Alignment (SSA) module anchors the solution using priors from medical foundation models (MedDINOv3), ensuring clinical plausibility. Experiments on synthetic and multi-center clinical datasets show PGMP outperforms state-of-the-art methods on unseen anatomy, setting new benchmarks in efficiency and diagnostic reliability. Code and data: https://github.com/ricoleehduu/PGMP.

📄 PDF Abstract BibTeX arXiv:2512.24260

Code (0)

등록된 구현이 없습니다.

Similar Papers 제목 키워드 기반

Deep Sinogram Completion with Image Prior for Metal Artifact Reduction in CT Images

2020-09-16 · Lequan Yu, Zhicheng Zhang, Xiaomeng Li, Lei Xing

Computed tomography (CT) has been widely used for medical diagnosis, assessment, and therapy planning and guidance. In reality, CT images may be affected adversely in the presence of metallic objects, which could lead to…

Computed Tomography (CT)Image GenerationMedical DiagnosisMetal Artifact Reduction

LumiTex: Towards High-Fidelity PBR Texture Generation with Illumination Context

2025-11-24 · Jingzhi Bao, Hongze Chen, Lingting Zhu, Chenyu Liu 외 arxiv

Physically-based rendering (PBR) provides a principled standard for realistic material-lighting interactions in computer graphics. Despite recent advances in generating PBR textures, existing methods fail to address two …

Deep learning based projection domain metal segmentation for metal artifact reduction in cone beam computed tomography

2022-08-17 · Harshit Agrawal, Ari Hietanen, Simo Särkkä

Metal artifact correction is a challenging problem in cone beam computed tomography (CBCT) scanning. Metal implants inserted into the anatomy cause severe artifacts in reconstructed images. Widely used inpainting-based m…

AnatomyDeep LearningMetal Artifact ReductionSegmentation

Projection Inpainting Using Partial Convolution for Metal Artifact Reduction

2020-05-02 · Lin Yuan, Yixing Huang, Andreas Maier

In computer tomography, due to the presence of metal implants in the patient body, reconstructed images will suffer from metal artifacts. In order to reduce metal artifacts, metals are typically removed in projection ima…

Metal Artifact Reductionvalid

Generative Mask Pyramid Network for CT/CBCT Metal Artifact Reduction with Joint Projection-Sinogram Correction

2019-06-29 · Haofu Liao, Wei-An Lin, Zhimin Huo, Levon Vogelsang 외

A conventional approach to computed tomography (CT) or cone beam CT (CBCT) metal artifact reduction is to replace the X-ray projection data within the metal trace with synthesized data. However, existing projection or si…

Computed Tomography (CT)Metal Artifact Reduction