Poisson Flow Consistency Training
The Poisson Flow Consistency Model (PFCM) is a consistency-style model based on the robust Poisson Flow Generative Model++ (PFGM++) which has achieved success in unconditional image generation and CT image denoising. Yet the PFCM can only be trained in distillation which limits the potential of the PFCM in many data modalities. The objective of this research was to create a method to train the PFCM in isolation called Poisson Flow Consistency Training (PFCT). The perturbation kernel was leveraged to remove the pretrained PFGM++, and the sinusoidal discretization schedule and Beta noise distribution were introduced in order to facilitate adaptability and improve sample quality. The model was applied to the task of low dose computed tomography image denoising and improved the low dose image in terms of LPIPS and SSIM. It also displayed similar denoising effectiveness as models like the Consistency Model. PFCT is established as a valid method of training the PFCM from its effectiveness in denoising CT images, showing potential with competitive results to other generative models. Further study is needed in the precise optimization of PFCT and in its applicability to other generative modeling tasks. The framework of PFCT creates more flexibility for the ways in which a PFCM can be created and can be applied to the field of generative modeling.
Code (0)
등록된 구현이 없습니다.
Tasks
Image GenerationImage DenoisingSimilar Papers 제목 키워드 기반
PPFM: Image denoising in photon-counting CT using single-step posterior sampling Poisson flow generative models
Diffusion and Poisson flow models have shown impressive performance in a wide range of generative tasks, including low-dose CT image denoising. However, one limitation in general, and for clinical applications in particu…
DenoisingImage DenoisingPFCM: Poisson flow consistency models for low-dose CT image denoising
X-ray computed tomography (CT) is widely used for medical diagnosis and treatment planning; however, concerns about ionizing radiation exposure drive efforts to optimize image quality at lower doses. This study introduce…
Computed Tomography (CT)DenoisingImage DenoisingMedical Diagnosis+1ResPF: Residual Poisson Flow for Efficient and Physically Consistent Sparse-View CT Reconstruction
Sparse-view computed tomography (CT) is a practical solution to reduce radiation dose, but the resulting ill-posed inverse problem poses significant challenges for accurate image reconstruction. Although deep learning an…
Computed Tomography (CT)CT ReconstructionImage GenerationImage ReconstructionProFlow: Zero-Shot Physics-Consistent Sampling via Proximal Flow Guidance
Inferring physical fields from sparse observations while strictly satisfying partial differential equations (PDEs) is a fundamental challenge in computational physics. Recently, deep generative models offer powerful data…
Flow Matching-Based PET Image Reconstruction
Generative models have shown strong potential for positron emission tomography (PET) image reconstruction. Although diffusion model-based reconstruction methods have demonstrated promising performance, they often require…
Image Reconstruction