Pose correction scheme for camera-scanning Fourier ptychography based on camera calibration and homography transform
Fourier ptychography (FP), as a computational imaging method, is a powerful tool to improve imaging resolution. Camera-scanning Fourier ptychography extends the application of FP from micro to macro creatively. Due to the non-ideal scanning of the camera driven by the mechanical translation stage, the pose error of the camera occurs, greatly degrading the reconstruction quality, while a precise translation stage is expensive and not suitable for wide-range imaging. Here, to improve the imaging performance of camera-scanning Fourier ptychography, we propose a pose correction scheme based on camera calibration and homography transform approaches. The scheme realizes the accurate alignment of data set and location error correction in the frequency domain. Simulation and experimental results demonstrate this method can optimize the reconstruction results and realize high-quality imaging effectively. Combined with the feature recognition algorithm, the scheme provides the possibility for applying FP in remote sensing imaging and space imaging.
Code (0)
등록된 구현이 없습니다.
Tasks
Camera CalibrationTranslationSimilar Papers 제목 키워드 기반
A Novel Hierarchical Light Field Coding Scheme Based on Hybrid Stacked Multiplicative Layers and Fourier Disparity Layers for Glasses-Free 3D Displays
This paper presents a novel hierarchical coding scheme for light fields based on transmittance patterns of low-rank multiplicative layers and Fourier disparity layers. The proposed scheme identifies multiplicative layers…
DecoderDifferentiable model-based adaptive optics for two-photon microscopy
Aberrations limit scanning fluorescence microscopy when imaging in scattering materials such as biological tissue. Model-based approaches for adaptive optics take advantage of a computational model of the optical setup. …
BIG-bench Machine LearningVocal Bursts Valence PredictionCMR motion artifact correction using generative adversarial nets
Cardiovascular Magnetic Resonance (CMR) plays an important role in the diagnoses and treatment of cardiovascular diseases while motion artifacts which are formed during the scanning process of CMR seriously affects docto…
Deep LearningEdge DetectionOnline Reconstruction of Indoor Scenes From RGB-D Streams
A system capable of performing robust online volumetric reconstruction of indoor scenes based on input from a handheld RGB-D camera is presented. Our system is powered by a two-pass reconstruction scheme. The first pass …
Unrolling the Shutter: CNN to Correct Motion Distortions
Row-wise exposure delay present in CMOS cameras is responsible for skew and curvature distortions known as the rolling shutter (RS) effect while imaging under camera motion. Existing RS correction methods resort to using…
Rolling Shutter Correction