Real-time deep learning phase imaging flow cytometer reveals blood cell aggregate biomarkers for haematology diagnostics
While analysing rare blood cell aggregates remains challenging in automated haematology, they could markedly advance label-free functional diagnostics. Conventional flow cytometers efficiently perform cell counting with leukocyte differentials but fail to identify aggregates with flagged results, requiring manual reviews. Quantitative phase imaging flow cytometry captures detailed aggregate morphologies, but clinical use is hampered by massive data storage and offline processing. Incorporating hidden biomarkers into routine haematology panels would significantly improve diagnostics without flagged results. We present RT-HAD, an end-to-end deep learning-based image and data processing framework for off-axis digital holographic microscopy (DHM), which combines physics-consistent holographic reconstruction and detection, representing each blood cell in a graph to recognize aggregates. RT-HAD processes >30 GB of image data on-the-fly with turnaround time of <1.5 min and error rate of 8.9% in platelet aggregate detection, which matches acceptable laboratory error rates of haematology biomarkers and solves the big data challenge for point-of-care diagnostics.
Code (0)
등록된 구현이 없습니다.
Similar Papers 제목 키워드 기반
Label-free detection of Giardia lamblia cysts using a deep learning-enabled portable imaging flow cytometer
We report a field-portable and cost-effective imaging flow cytometer that uses deep learning to accurately detect Giardia lamblia cysts in water samples at a volumetric throughput of 100 mL/h. This flow cytometer uses le…
High-speed real-time single-pixel microscopy based on Fourier sampling
Single-pixel cameras based on the concepts of compressed sensing (CS) leverage the inherent structure of images to retrieve them with far fewer measurements and operate efficiently over a significantly broader spectral r…
compressed sensingImage ReconstructionImage RestorationVocal Bursts Intensity PredictionAccuracy of Real-Time Echo-Planar Imaging Phase Contrast MRI
Compared with CINE phase contrast MRI (CINE-PC), echo-planar imaging phase contrast (EPI-PC) can achieve realtime quantification of blood flow, with lower SNR. In this study, the pulsating real model of the simulated cer…
Machine Learning for Flow Cytometry Data Analysis
Flow cytometry mainly used for detecting the characteristics of a number of biochemical substances based on the expression of specific markers in cells. It is particularly useful for detecting membrane surface receptors,…
ClusteringDiagnosticEffect of Channel Geometry and Flow Rates in Hydrodynamic Focusing on Impedance Detection of Circulating Tumor Cells
Cells, other than their biological properties, have different electric and physical properties. In an impedance cytometer, cells should pass one by one in the detection region where pairs of electrodes are located. When …