Relative Afferent Pupillary Defect Screening through Transfer Learning
Abnormalities in pupillary light reflex can indicate optic nerve disorders that may lead to permanent visual loss if not diagnosed in an early stage. In this study, we focus on relative afferent pupillary defect (RAPD), which is based on the difference between the reactions of the eyes when they are exposed to light stimuli. Incumbent RAPD assessment methods are based on subjective practices that can lead to unreliable measurements. To eliminate subjectivity and obtain reliable measurements, we introduced an automated framework to detect RAPD. For validation, we conducted a clinical study with lab-on-a-headset, which can perform automated light reflex test. In addition to benchmarking handcrafted algorithms, we proposed a transfer learning-based approach that transformed a deep learning-based generic object recognition algorithm into a pupil detector. Based on the conducted experiments, proposed algorithm RAPDNet can achieve a sensitivity and a specificity of 90.6% over 64 test cases in a balanced set, which corresponds to an AUC of 0.929 in ROC analysis. According to our benchmark with three handcrafted algorithms and nine performance metrics, RAPDNet outperforms all other algorithms in every performance category.
Code (0)
등록된 구현이 없습니다.
Tasks
BenchmarkingObject RecognitionSpecificityTransfer LearningSimilar Papers 제목 키워드 기반
VR-SFT: Reproducing Swinging Flashlight Test in Virtual Reality to Detect Relative Afferent Pupillary Defect
The relative afferent asymmetry between two eyes can be diagnosed using swinging flashlight test, also known as the alternating light test. This remains one of the most used clinical tests to this day. Despite the swingi…
Wearable multi-color RAPD screening device
In this work, we developed a wearable, head-mounted device that automatically calculates the precise Relative Afferent Pupillary Defect (RAPD) value of a patient. The device consists of two RGB LEDs, two infrared cameras…
Automated Pupillary Light Reflex Test on a Portable Platform
In this paper, we introduce a portable eye imaging device denoted as lab-on-a-headset, which can automatically perform a swinging flashlight test. We utilized this device in a clinical study to obtain high-resolution rec…
SpecificityPupillary activity in areas of interest from visual stimuli for neonatal pain assessment
This paper compares the pupillary activity index to traditional eye-tracking metrics like the fixation count and duration in assessing neonatal pain. It explores the benefits of incorporating pupillary activity measures …
Diffuse to Detect: Generative Diffusion Models for Unsupervised IC Anomaly Detection
Latent defect screening is challenged by extremely low failure rates, high-dimensional test data, and absence of labeled anomalies. We propose the first unsupervised anomaly detection framework incorporating a Diffusion …
Unsupervised Anomaly DetectionFeature Engineering