Robust and Explainable Bicuspid Aortic Valve Diagnosis Using Stacked Ensembles on Echocardiography
Transthoracic echocardiography (TTE) is the first-line imaging modality for diagnosing bicuspid aortic valve (BAV), yet diagnostic performance varies with operator expertise and image quality. We developed an explainable AI model that distinguishes BAV from tricuspid aortic valves (TAV) using routinely acquired parasternal long-axis (PLAX) cine loops. A multi-backbone video ensemble was trained and evaluated using a leakage-aware, stratified outer cross-validation protocol on $N{=}90$ patient studies (48 BAV, 42 TAV). Across fixed outer splits and 10 random seeds, the calibrated stacked ensemble achieved an outer-CV F1-score of $0.907$ and recall of $0.877$. Frame-level Grad-CAM localized salient evidence to the aortic root and leaflet plane, while globally aggregated SHAP values quantified each video backbone's contribution to the stacked prediction, enabling transparent, case-level auditability. These findings indicate that PLAX-based video ensembles can support reliable BAV/TAV classification from routine echocardiographic cine loops and may facilitate earlier detection in non-specialist or resource-limited clinical settings.
Code (0)
등록된 구현이 없습니다.
Similar Papers 제목 키워드 기반
Controlled Comparison of Simulated Hemodynamics across Tricuspid and Bicuspid Aortic Valves
Bicuspid aortic valve is the most common congenital heart defect, affecting 1-2% of the global population. Patients with bicuspid valves frequently develop dilation and aneurysms of the ascending aorta. Both hemodynamic …
Simulation-Based Design of Bicuspidization of the Aortic Valve
Objective: Severe congenital aortic valve pathology in the growing patient remains a challenging clinical scenario. Bicuspidization of the diseased aortic valve has proven to be a promising repair technique with acceptab…
A deep learning approach to using wearable seismocardiography (SCG) for diagnosing aortic valve stenosis and predicting aortic hemodynamics obtained by 4D flow MRI
In this paper, we explored the use of deep learning for the prediction of aortic flow metrics obtained using 4D flow MRI using wearable seismocardiography (SCG) devices. 4D flow MRI provides a comprehensive assessment of…
Deep LearningTowards Patient-Specific Surgical Planning for Bicuspid Aortic Valve Repair: Fully Automated Segmentation of the Aortic Valve in 4D CT
The bicuspid aortic valve (BAV) is the most prevalent congenital heart defect and may require surgery for complications such as stenosis, regurgitation, and aortopathy. BAV repair surgery is effective but challenging due…
Computed Tomography (CT)SegmentationTemporal SequencesAutomatic Aortic Valve Pathology Detection from 3-Chamber Cine MRI with Spatio-Temporal Attention Maps
The assessment of aortic valve pathology using magnetic resonance imaging (MRI) typically relies on blood velocity estimates acquired using phase contrast (PC) MRI. However, abnormalities in blood flow through the aortic…
3D ClassificationClassification