Second Order Kinematic Surface Fitting in Anatomical Structures

2024-01-29 · Wilhelm Wimmer, Hervé Delingette

Symmetry detection and morphological classification of anatomical structures play pivotal roles in medical image analysis. The application of kinematic surface fitting, a method for characterizing shapes through parametric stationary velocity fields, has shown promising results in computer vision and computer-aided design. However, existing research has predominantly focused on first order rotational velocity fields, which may not adequately capture the intricate curved and twisted nature of anatomical structures. To address this limitation, we propose an innovative approach utilizing a second order velocity field for kinematic surface fitting. This advancement accommodates higher rotational shape complexity and improves the accuracy of symmetry detection in anatomical structures. We introduce a robust fitting technique and validate its performance through testing on synthetic shapes and real anatomical structures. Our method not only enables the detection of curved rotational symmetries (core lines) but also facilitates morphological classification by deriving intrinsic shape parameters related to curvature and torsion. We illustrate the usefulness of our technique by categorizing the shape of human cochleae in terms of the intrinsic velocity field parameters. The results showcase the potential of our method as a valuable tool for medical image analysis, contributing to the assessment of complex anatomical shapes.

📄 PDF Abstract BibTeX arXiv:2401.16035

Code (0)

등록된 구현이 없습니다.

Tasks

Medical Image AnalysisSymmetry Detection

Similar Papers 제목 키워드 기반

Anatomically Constrained Implicit Face Models

2023-12-12 · CVPR 2024 1 · Prashanth Chandran, Gaspard Zoss

Coordinate based implicit neural representations have gained rapid popularity in recent years as they have been successfully used in image, geometry and scene modeling tasks. In this work, we present a novel use case for…

AnatomyFace Model

Robust Cochlear Modiolar Axis Detection in CT

2019-07-03 · Wilhelm Wimmer, Clair Vandersteen, Nicolas Guevara, Marco Caversaccio 외

The cochlea, the auditory part of the inner ear, is a spiral-shaped organ with large morphological variability. An individualized assessment of its shape is essential for clinical applications related to tonotopy and coc…

Computed Tomography (CT)

Equivariant Systems Theory and Observer Design for Second Order Kinematic Systems on Matrix Lie Groups

2021-05-11 · Yonhon Ng, Pieter van Goor, Tarek Hamel, Robert Mahony

This paper presents the equivariant systems theory and observer design for second order kinematic systems on matrix Lie groups. The state of a second order kinematic system on a matrix Lie group is naturally posed on the…

Attitude Observation for Second Order Attitude Kinematics

2021-04-14 · Yonhon Ng, Pieter van Goor, Robert Mahony, Tarek Hamel

This paper addresses the problem of estimating the attitude and angular velocity of a rigid object by exploiting its second order kinematic model. The approach is particularly useful in cases where angular velocity measu…