Semiconductor Devices Condition Monitoring Using Harmonics in Inverter Control Variables
The health status of power semiconductor devices in power converters is important but difficult to monitor. This paper analyzes the relationship between harmonics in inverter control variables and a health precursor (the on-state voltage Von of power semiconductor devices). Based on the analysis, harmonics can estimate Von without adding extra sensing circuits. The method is validated through simulations.
Code (0)
등록된 구현이 없습니다.
Similar Papers 제목 키워드 기반
Optimal Control of Grid-Interfacing Inverters With Current Magnitude Limits
Grid-interfacing inverters act as the interface between renewable resources and the electric grid, and have the potential to offer fast and programmable controls compared to synchronous generators. With this flexibility …
Model Predictive ControlSelective Harmonic Elimination in a Cascaded H-Bridge Multilevel Inverter fed by High-Frequency Isolated DC-DC Converter
In recent years, the use of multilevel inverter has become popular due to its many advantages. Due to the popularity of multilevel inverters in industries and in applications that require a wide range of voltages, there …
Safe Control of Grid-Interfacing Inverters with Current Magnitude Limits
Grid-interfacing inverters allow renewable resources to be connected to the electric grid and offer fast and programmable control responses. However, inverters are subject to significant physical constraints. One such co…
Minimization of THD in Nine Level Cascaded H-Bridge Inverter Using Artificial Neural Network
Multilevel inverter converts different level DC voltage to AC voltage. It has wide interest in power industry especially in high power applications. In power electronic equipment the major drawback is the harmonics. Seve…
On the damping of power systems during inverter-based blackstart
The massive deployment of inverter-based generation poses several challenges to system operators but also offers new opportunities. In the context of grid recovery, inverter-based generation is expected to take over new …