SPECMAR: Fast Heart Rate Estimation from PPG Signal using a Modified Spectral Subtraction Scheme with Composite Motion Artifacts Reference Generation
The task of heart rate estimation using photoplethysmographic (PPG) signal is challenging due to the presence of various motion artifacts in the recorded signals. In this paper, a fast algorithm for heart rate estimation based on modified SPEctral subtraction scheme utilizing Composite Motion Artifacts Reference generation (SPECMAR) is proposed using two-channel PPG and three-axis accelerometer signals. First, the preliminary noise reduction is obtained by filtering unwanted frequency components from the recorded signals. Next, a composite motion artifacts reference generation method is developed to be employed in the proposed SPECMAR algorithm for motion artifacts reduction. The heart rate is then computed from the noise and motion artifacts reduced PPG signal. Finally, a heart rate tracking algorithm is proposed considering neighboring estimates. The performance of the SPECMAR algorithm has been tested on publicly available PPG database. The average heart rate estimation error is found to be 2.09 BPM on 23 recordings. The Pearson correlation is 0.9907. Due to low computational complexity, the method is faster than the comparing methods. The low estimation error, smooth and fast heart rate tracking makes SPECMAR an ideal choice to be implemented in wearable devices.
Code (1)
Tasks
Heart rate estimationMethods 이 논문이 사용한 방법론
Similar Papers 제목 키워드 기반
Deep adaptative spectral zoom for improved remote heart rate estimation
Recent advances in remote heart rate measurement, motivated by data-driven approaches, have notably enhanced accuracy. However, these improvements primarily focus on recovering the rPPG signal, overlooking the implicit c…
Heart rate estimationFastBVP-Net: a lightweight pulse extraction network for measuring heart rhythm via facial videos
Remote photoplethysmography (rPPG) is an attractive camera-based health monitoring method that can measure the heart rhythm from facial videos. Many well-established deep-learning models have been reported to measure hea…
Heart rate estimationHeart Rate VariabilityRhythmA Self-Supervised Algorithm for Denoising Photoplethysmography Signals for Heart Rate Estimation from Wearables
Smart watches and other wearable devices are equipped with photoplethysmography (PPG) sensors for monitoring heart rate and other aspects of cardiovascular health. However, PPG signals collected from such devices are sus…
DenoisingHeart rate estimationHeart Rate VariabilityPhotoplethysmography (PPG)HeartBEAT: Heart Beat Estimation through Adaptive Tracking
In this paper, we propose an algorithm denoted as HeartBEAT that tracks heart rate from wrist-type photoplethysmography (PPG) signals and simultaneously recorded three-axis acceleration data. HeartBEAT contains three maj…
Photoplethysmography (PPG)Heart Rate Estimation from Ballistocardiography Based on Hilbert Transform and Phase Vocoder
This paper presents a robust method to monitor heart rate (HR) from BCG (Ballistocardiography) signal, which is acquired from the sensor embedded in a chair or a mattress. The proposed algorithm addresses the shortfalls …
Heart rate estimation