The impact of varying electrical stimulation parameters on neuromuscular response
High density neurostimulation systems are coming to market to help spinal cord injury patients by stimulating and recording neuromuscular function. However, the parameter space that these systems have to explore is exceedingly large, and would need an artificial intelligence (AI) system to optimize. We need a platform that will allow us to determine the optimal parameter space for these systems. Our project aims to build a platform for mapping and controlling neuromuscular activity, as a high-throughput testbed for implementing and testing closed-loop neuromuscular activity. This abstract presents the first phase (the mapping phase) of building that testbed by combining multi-electrode stimulation/recording with visual motion-tracking. A 3D-printed rectangular raceway was used with 4 pairs of differential recording electrodes, and two stimulation electrodes embedded in the raceway bed. Non-anesthetized earthworms were placed on the raceway with their head section on the stimulating electrodes. Bipolar sinusoidal stimulation pulses of a range of voltages (2 to 6Vp-p), pulse durations (2 ms to 6.7 ms), and a burst rate of 1 pulse per second were applied, and action potentials and physical motion were recorded and analyzed. Action potentials were found to correlate with expansion/contraction displacements of worm segments, and voltage increases were shown to increase action potential propagation amplitude. Using the multiple electrode recording allowed us to capture the wave propagation of action potential pulse over the length of the worm. Feasibility of a platform to simultaneously monitor action potentials and motion of earthworms with real-time mapping was demonstrated.
Code (0)
등록된 구현이 없습니다.
Similar Papers 제목 키워드 기반
The Dynamic Shift of Neuron Excitability Observed with Enveloped High Frequency Stimulation
Neuronal excitability is known to be affected by transcranial electrical stimulation. However, due to the existence of both excitatory and inhibitory neurons in the cortex, the mechanism of neuronal excitability shift is…
I am Robot: Neuromuscular Reinforcement Learning to Actuate Human Limbs through Functional Electrical Stimulation
Human movement disorders or paralysis lead to the loss of control of muscle activation and thus motor control. Functional Electrical Stimulation (FES) is an established and safe technique for contracting muscles by stimu…
Deep Reinforcement LearningReinforcement Learning (RL)RISE Controller Tuning and System Identification Through Machine Learning for Human Lower Limb Rehabilitation via Neuromuscular Electrical Stimulation
Neuromuscular electrical stimulation (NMES) has been effectively applied in many rehabilitation treatments of individuals with spinal cord injury (SCI). In this context, we introduce a novel, robust, and intelligent cont…
A Static Distributed-parameter Circuit Model Explains Electrical Stimulation on the Neuromuscular System
Finite Element Modeling (FEM) has been widely used to model the electric field distribution, to study the interaction between stimulation electrodes and neural tissue. However, due to the insufficient computational capab…
The Role of Contraction Mode in Determining Exercise Tolerance, Torque-Duration Relationship, and Neuromuscular Fatigue
Purpose: Critical torque (CT) and work done above it (W') are key predictors of exercise performance associated with neuromuscular fatigue. The aim of the present study was to understand the role of the metabolic cost of…